5-4
USER INTERFACE
Model C303 & C314
User Interface
5
CHK REFRIG SYS PSI
The compressor is out on high head pressure. When
this fault occurs, the machine automatically turns off.
The fault clears when the condition is corrected.
THERMISTOR SHORT
One of the barrel (freezing cylinder) thermistor
probes is faulty.
THERMISTOR OPEN
One of the barrel (freezing cylinder) thermistor
probes is faulty.
SYRUP PRESS LOW
When the syrup out indicator displays a lack of syrup,
the barrel enters the Hold mode. No refrigeration or
product flow from the flow control is allowed. The
beater will operate as long as the barrel temperature
is below 50°F (10°C). (See Syrup Out Indicator on
CO
2
PRESSURE LOW—
When the CO
2
out indicator displays a lack of CO
2
, a
60-second internal timer will start. If the CO
2
is not
replenished at the end of the 60 seconds, both freez-
ing cylinders will shut down and this fault message
will appear. Replenish the CO
2
, and the fault mes-
sage and warning tone will clear.
H
2
O PRESSURE LOW
When the water out indicator displays a lack of water,
a 60-second internal timer will start. If the water is not
replenished at the end of the 60 seconds, all freezing
cylinders will shut down and this fault message will
appear. Replenish the water and the fault message
and warning tone will clear.
BRL NOT COOLING
A freezing cylinder check has been established for
the Auto mode of operation. If a freezing cylinder
enters the Auto mode, the control will check product
temperature. After 5-minutes, it will again check prod-
uct temperature. If product temperature does not
drop in that 5-minute span, the freezing cylinder will
shut down and this message will appear on the fault
screen. For this check to be valid, the
product temperature must be above 40°F (4.4°C).
FAULT DESCRIPTION
BARREL 1
CHK REFRIG SYS PSI
CLR
+ + +
SEL
FAULT DESCRIPTION
BARREL 1
THERMISTOR SHORT
CLR
+ + +
SEL
FAULT DESCRIPTION
BARREL 1
THERMISTOR OPEN
CLR
+ + +
SEL
FAULT DESCRIPTION
BARREL 1
SYRUP PRESS LOW
CLR
+ + +
SEL
FAULT DESCRIPTION
BARREL 1
CO2 PRESSURE LOW
CLR
+ + +
SEL
FAULT DESCRIPTION
BARREL 1
H2O PRESSURE LOW
CLR
+ + +
SEL
FAULT DESCRIPTION
BARREL 1
BARREL NOT COOLING
CLR
+ + +
SEL
Summary of Contents for C303
Page 14: ...3 4 SAFETY Model C303 C314 Safety 3 Notes...
Page 41: ...OPERATING PROCEDURES 6 13 Model C303 C314 Operating Procedures 6...
Page 43: ...7 2 OPERATOR CHECKLIST Model C303 C314 Operator Checklist 7 Notes...
Page 47: ...9 2 PARTS REPLACEMENT SCHEDULE Model C303 C314 Parts Replacement Schedule 9 Notes...
Page 53: ...11 4 LIMITED WARRANTY ON PARTS Model C303 C314 Limited Warranty on Parts 11 Notes...