5-10
USER INTERFACE
Model C303 & C314
User Interface
5
Audio Alarm Silencer
The audio alarm will be disabled if the ALARM SILENCE
key is pressed. If a fault condition occurs or the system
mode changes, the audio alarm will be re-enabled
automatically. If the audio alarm is silenced for greater
than 30-minutes without correcting the fault, it will be re-
enabled automatically.
Product Light
When the light is continuously lit (not flashing), it
indicates that there is an OUT condition for syrup, water,
or CO
2
.
When the light is flashing, it indicates that the
product is not at serving viscosity. This will occur
during the initial freeze down, a defrost cycle, and
during power saver modes
Sampling Valve
The sampling valve is located behind the lower front
panel. The sampling valve is used to obtain a brix
reading.
Daily Procedures
The following procedure should be performed daily.
Remove the splash shield and front drip tray. Take these
parts to the sink and brush-clean them.
Re-install the parts onto the freezer. Use a clean,
sanitized towel and wipe down the front of the machine,
including the doors and spouts.