USER INTERFACE
5-5
Model C303 & C314
User Interface
5
BRL TEMP 2 HIGH
A maximum allowable product temperature has been
established to prevent product from excessive heat-
ing. If the product exceeds 120°F (49°C) for any rea-
son (in any mode of operation), the entire unit shuts
down.
BEATER OVER CURRENT
When the unit experiences a Beater Over Current
fault, one of the following two events will occur.
•
If the barrel temperature is above 40°F (4.4°C)
the software will generate a Beater Overload
fault, i.e. the overload is not the result of a
frozen barrel. The fault will be placed in the
Fault History, and the barrel will be placed into
the OFF mode. Pressing the AUTO key will
clear the fault and attempt to operate the barrel
in the Auto mode. The fault may also be cleared
in the Fault Description menu. If the overload
still exists, another Beater Overload fault will be
generated.
•
If the barrel temperature is at or below 40°F
(4.4°C) the software will enter the Beater
Overload Recovery process, i.e., the overload
may be the result of a frozen barrel.
Beater Overload Recovery Process
The barrel will be placed in the DEFROST PENDING
mode. This is indicated as a flashing "DEF" mode on
the display. If the opposing barrel is refrigerating or
defrosting, the barrel in recovery will remain in the
DEFROST PENDING mode. If the opposing barrel is
not refrigerating and is not defrosting, the barrel in
recovery will switch from DEFROST PENDING mode
into the DEFROST mode.
Once the recovery barrel is in the DEFROST mode,
the barrel will begin heating, but the software will not
attempt to run the beater for 10-minutes. This gives
the beater motor time to cool down from its internal
overload. If the barrel reaches 50
°
F (10
°
C) before the
10-minute cooling time expires, the software will stop
heating the barrel. If the barrel temperature falls to
35°F (1.7
°
C), heating will resume.
When the barrel temperature exceeds 40
°
F (4.4
°
C)
and the 10-minute cooling time has expired, the soft-
ware will attempt to run the beater.
If the current sensor senses current flowing through
the beater motor, the software will wait for 30 sec-
onds (even if the barrel temperature has reached
50°F/10
°
C) in case the barrel temperature falls due
to the beater stirring the product. After the 30 sec-
onds, the DEFROST mode operation will continue
until the barrel temperature reaches 50°F (10
°
C), at
which time it will switch to the Auto mode and resume
normal operation.
Note:
If the beater fails to start, or if another internal
overload occurs, the recovery process will be repeated
from the beginning. If a third internal overload occurs, a
Beater Overload fault will be generated, and the barrel
will be placed into the Off mode.
SET CLOCK.
Use the AUTO (- ->) and OFF (<- -) keys to place the
cursor under the element to be set (hour, minute,
month, day, or year). Use the PRIME (+++) and
BEATER (- - -) keys to increase or decrease the time/
date settings.
Note:
The clock is programmed with military time.
If an invalid date is entered, (example: if the date
entered exceeds the days of the month) the LCD will
display the following screen.
FAULT DESCRIPTION
BARREL 1
BARREL TEMP 2 HIGH
CLR
+ + +
SEL
SET CLOCK
14:30
7/25/10
<- - - -> + + +
- - -
SEL
SET CLOCK
14:30
INVALID DATE
SEL
7/25/10
Summary of Contents for C303
Page 14: ...3 4 SAFETY Model C303 C314 Safety 3 Notes...
Page 41: ...OPERATING PROCEDURES 6 13 Model C303 C314 Operating Procedures 6...
Page 43: ...7 2 OPERATOR CHECKLIST Model C303 C314 Operator Checklist 7 Notes...
Page 47: ...9 2 PARTS REPLACEMENT SCHEDULE Model C303 C314 Parts Replacement Schedule 9 Notes...
Page 53: ...11 4 LIMITED WARRANTY ON PARTS Model C303 C314 Limited Warranty on Parts 11 Notes...