SAFETY
3-3
Model C303 & C314
Safety
3
maintain product temperature under 41°F (5
C). Any
product being added to this machine must be below 41
F
(5
C). Failure to follow this instruction may result in
health hazards and poor freezer performance.
Do not
obstruct air intake and discharge openings.
Air-cooled units require a minimum of 3 in. (76 mm) of
airspace on both sides, 3 in. (76 mm) at the rear, and 12
in. (305 mm) on the top of the unit. Minimum air
clearances must be met to ensure adequate airflow for
optimum performance.
For indoor Use Only:
This unit is designed to operate
indoors, under normal ambient temperatures of 70°F to
75°F (21°C to 24°C). The freezer has successfully
performed in high ambient temperatures of 104°F (40°C)
at reduced capacities.
Do not
run the machine without product. Failure to follow
this instruction can result in damage to the machine.
Noise Level:
Airborne noise emission does not exceed
78 dB(A) when measured at a distance of 3.3 ft. (1.0 m)
from the surface of the machine and at a height of 5.25 ft
(1.6 m) from the floor.
WARNING! Asphyxiation Hazard!
If used with CO
2
(Carbon Dioxide) or N2 (Nitrogen),
always make sure the area is well ventilated.
Vent exhaust gas to outside atmosphere using a hose.
Failure to do so can cause serious injury.
Summary of Contents for C303
Page 14: ...3 4 SAFETY Model C303 C314 Safety 3 Notes...
Page 41: ...OPERATING PROCEDURES 6 13 Model C303 C314 Operating Procedures 6...
Page 43: ...7 2 OPERATOR CHECKLIST Model C303 C314 Operator Checklist 7 Notes...
Page 47: ...9 2 PARTS REPLACEMENT SCHEDULE Model C303 C314 Parts Replacement Schedule 9 Notes...
Page 53: ...11 4 LIMITED WARRANTY ON PARTS Model C303 C314 Limited Warranty on Parts 11 Notes...