CE CONFORMITY DECLARATION

Ref. No. 58.RT.01.2007/1/B

We,

ZAK

Ł

AD ELEKTRONICZNY TATAREK Jerzy Tatarek

75 Swieradowska St. , 50-559 Wroclaw

declare under our sole responsibility that

the product: Regulator of heating system with solar collector

model: RT-08, RT-08K, RT-08P, RT-08G, RT-08G-BUF

PN-EN 55022: 2000 -

(EMC)- IT devices

Characteristics of radioelectric noises. Acceptable levels and measurement methods

:

Laboratory IASE 51-618 Wroclaw, 1 Wystawowa st.

Test report No.

39/DL/I/07 of 22.06.2007
41/DL/I/07 of 03.07.2007

Place of issue:

Manufacturer representative:

Wroclaw

Miros

ł

aw Zas

ę

pa

Date of issue:

Position:

08.2007

Konstruktor

is in conformity with the basic requirements included in Directive EMC 2004/108/WE of 15.12.2004 (the
electromagnetic compatibility law of 13.04.07) and Directive LVD 2006/95/WE of 21.08.07 (Laws Journal
of 2007 No. 155 pos. 1098) regarding the requirements for electric devices.

To the conformity evaluation the following harmonized standards were used:

PN-EN 60730-2-1: 2002 -

Automatic electric regulators for house usage and the like. Part 2-1:

Specific requirements regarding electric regulators for electric house
devices

PN-EN 60730-1: 2002 -

Automatic electric regulators for house usage and the like.
Part 1: General requirements.

Electromagnetic compatibility

Complementary information

Electronic Engineering Plant TATAREK

has initiated management system and complies with the following standard :

ISO9001: 2000 CERTIFICATE No. 133/2004 of 01.2004

Polish Foreign Trade Chamber

The last two digits of the year in which the CE marking was affixed: 07

Fig. 1b Alternative operation diagram of the buffer type COMBO, that is, the WAW container is
included in the buffer.

FIREPLACE

WAW

CH

CH= Central Heating
WAW=Warm Applicable Water

WAW

Warm Applicable Water container (boiler)

FIREPLACE

Water jacket fireplace

BUF

Buffer container

CH

Central heating system

T1

Temperature sensor of the buffer container

T2

Temperature sensor of the WAW container

T3

Temperature sensor of the fireplace water jacket

P1

Pump loading the WAW from fireplace

P2

Pump loading the buffer container

P3

Circulating pump CH

PP

Electronically controlled choke valve of the fireplace

!

In case of using the COMBO buffer (the WAW is inside the buffer) you need to change the

<93> BUFFER COMBO to ON because for such a configuration the loading pump of the WAW
receives heat from the fireplace and not from the buffer (see fid.1)

2.1

C

hoke valve operation

The choke valve regulates an air supply to the combustion chamber, which allows the temperature of
the fireplace water jacket to be kept at the preset value. The task is realized by comparing the
temperature of the water jacket(T3) and preset temperature (the <20>
parameter) and then by gradual opening/shutting the choke valve. The change of the choke valve
position is done every 20secs
The shutdown of the RT-08G-BUF control unit automatically causes the choke valve to be set at the
rest position defined by the <50>

parameter (Default setting is 0% - full shut-

off).

”FIREPLACE Temp.”

ChokeV State OFF

Summary of Contents for RT-08G-BUF

Page 1: ...ion conditions 0 50 C humidity 10 90 Housing protection class Fuse 6 3A 250V Number of outputs to control pumps Number of nonvoltage outputs 1 Number of outputs to control the choke valve drive Number...

Page 2: ...temperature of heat source BUFFER for standard configuration FIREPLACE for a configuration with the buffer type COMBO see fig 1 exceeds the value and is higher than the WAW accumulator temperature T2...

Page 3: ...d ISO9001 2000 CERTIFICATE No 133 2004 of 01 2004 Polish Foreign Trade Chamber The last two digits of the year in which the CE marking was affixed 07 Fig 1b Alternative operation diagram of the buffer...

Page 4: ...HE CONTROL UNIT MADE BY A USER CAN BE THE CAUSE OF SAFETY CONDITIONS DETERIORATION AND CAN EXPOSE THE USER TO ELECTRIC SHOCK OR DAMAGE DEVICES SUPPLIED Date of sale Seller s signature and stamp Zak ad...

Page 5: ...is equipped with the CONTROL relay whose contacts can be used e g to switch off another heat source when the fireplace works The parameter definesthefunctionof therelaymoreprecisely see PARAMETERS LEV...

Page 6: ...nged parameter not confirmed for 10 secs is not acceptedby thecontrolunit ON OFF CHOOSE CONFIRM Fig 2 Control panel view 1 Control unit status diode alarm red standby orange operation green manual MAN...

Page 7: ...only at unlocked password To unlock the password you need to input proper sequence of digits with the buttons With the CHOOSE button 7 to change the digits position and CONFIRM button 6 to acknowledge...

Page 8: ...urning off the pumps It prevents from often switchovers especially if there s another heat source in the heating system Buffer limit temperature at which the alarm generates 75 95 o C 85 o C Fireplace...

Page 9: ...he exceeding turns off the loading pump 42 Minimum temp of WAW 30 99 o C 50 o C Minimal temperature of WAW container The exceeding turns on the loading pump 43 Loading temp of WAW special 30 99 o C 65...