Icon of the

current mode

Selection of the mode

from the list (+/-)

Screen of the clock

Screen of pumps operation for the basic operation configuration

It

s a stable state, that is, in order to change it you need to press the CHOOSE button (7)

enables changing the operation mode of the fireplace and WAW

container.
Possible operation modes of the fireplace are as follows (described above):

Possible operation modes of the WAW container are as follows (described above):

Screen of the operation modes

MAN/OFF/AUTO/ON

OFF/SUMMER/ON/PRIORITY/CLOCK/SPECIAL

The screen shows the current time and the number of the activated time zone.

Time correction is possible after pressing the CONFIRM button (6) and the minutes field begins
blinking. The blinking value can be altered with the buttons

+

or

-

Pressing the CHOOSE

button (7) you come to the hours field that can be set also with the buttons

+

or

-

.

Pressing the CONFIRM button (6) confirms the changes (the clock field will stop blinking).

Normally the

equals to

0

namely the parameters aren

t available.

After changing the level to

1

,

2

,

3

or

4

successive screens show the values of the

parameters.
The last screen contains

****

after which it comes back to the above mentioned screens.

Screen of setting the parameters

parameters level

Screen of pumps operation for the alternative run configuration BUFFER COMBO

Temperature

of the water jacket of

the fireplace (T3)

WAW pump

doesn

t run

T1 - temperature

of the buffer

State of

the CONTROL relay

Operation mode

of the WAW

Time

zone

Current

time

BUF pump runs

CH pump

runs

T2 - temperature

of the WAW

PARAMETERS

Parameter

name

Unit

Upper and

lower thershold

of the changes

Parameter value

(change with +/-)

!

PARAMETERS ADJUST THE CONTROL UNIT TO THE PROPERTIES OF

THE FIREPLACE AND CENTRAL HEATING SYSTEM. THEIR CHANGE
OUGHT TO BE CONSULTED WITH THE FIREPLACE PRODUCER.
ILL-CONSIDERED MODIFICATIONS CAN CAUSE UNSTABLE AND
INEFFICIENT OPERATION OF THE SYSTEM

Summary of Contents for RT-08G-BUF

Page 1: ...ion conditions 0 50 C humidity 10 90 Housing protection class Fuse 6 3A 250V Number of outputs to control pumps Number of nonvoltage outputs 1 Number of outputs to control the choke valve drive Number...

Page 2: ...temperature of heat source BUFFER for standard configuration FIREPLACE for a configuration with the buffer type COMBO see fig 1 exceeds the value and is higher than the WAW accumulator temperature T2...

Page 3: ...d ISO9001 2000 CERTIFICATE No 133 2004 of 01 2004 Polish Foreign Trade Chamber The last two digits of the year in which the CE marking was affixed 07 Fig 1b Alternative operation diagram of the buffer...

Page 4: ...HE CONTROL UNIT MADE BY A USER CAN BE THE CAUSE OF SAFETY CONDITIONS DETERIORATION AND CAN EXPOSE THE USER TO ELECTRIC SHOCK OR DAMAGE DEVICES SUPPLIED Date of sale Seller s signature and stamp Zak ad...

Page 5: ...is equipped with the CONTROL relay whose contacts can be used e g to switch off another heat source when the fireplace works The parameter definesthefunctionof therelaymoreprecisely see PARAMETERS LEV...

Page 6: ...nged parameter not confirmed for 10 secs is not acceptedby thecontrolunit ON OFF CHOOSE CONFIRM Fig 2 Control panel view 1 Control unit status diode alarm red standby orange operation green manual MAN...

Page 7: ...only at unlocked password To unlock the password you need to input proper sequence of digits with the buttons With the CHOOSE button 7 to change the digits position and CONFIRM button 6 to acknowledge...

Page 8: ...urning off the pumps It prevents from often switchovers especially if there s another heat source in the heating system Buffer limit temperature at which the alarm generates 75 95 o C 85 o C Fireplace...

Page 9: ...he exceeding turns off the loading pump 42 Minimum temp of WAW 30 99 o C 50 o C Minimal temperature of WAW container The exceeding turns on the loading pump 43 Loading temp of WAW special 30 99 o C 65...

Page 10: ...uttons or Pressing theCONFIRM button 6 confirmsthechanges theclockfieldwillstopblinking Normallythe equalsto 0 namelytheparametersaren tavailable After changing the level to 1 2 3 or 4 successive scre...