4.17 VALVE KITS
12VDC KITS / 24VDC KITS
YE-VKG-PD
YE-VK-PF
YE-VKG-PF
YE-VK-PH
YE-VKG-PH
YE-VK-PJ
YE-VK-PL
Each kit includes a water valve with plug-in electrical connection(s) and an interface control for “plug and play” wiring for power, water
valve, monitor, joystick control and an extra operator station. The installer will need to mount the water valve and the interface box.
The interface box is weatherproof and may be installed at any convenient location to route and connect all control system cables.
4.17.1 VALVE MOUNTING
The water valve may be mounted at any location within the plumbing and at any orientation. The wiring and connector from the valve
actuator should be protected from pulling and abrasion. The valve inlet and outlet connections and the valve/actuator dimensions
are shown in the table below.
TFT
Valve Kit #
TFT
Valve #
"Inlet and Outlet
Thread Connections"
Overall Dimensions inches (mm)
Face-to Face
Width
Height
YE-VKG-PD
Y7061
1" NPT
3.6 (91)
7.1 (180)
8.4 (213)
YE-VK-PF
Y7003
1 1/2" NPT
4.8 (122)
7.1 (180)
9.4 (239)
YE-VKG-PF
Y7062
YE-VK-PH
Y7000
2" NPT
5.4 (137)
7.1 (180)
10.0 (254)
YE-VKG-PH
Y7063
YE-VK-PJ
Y7001
2 1/2" NPT
6.7 (170)
8.6 (218)
13.7 (348)
YE-VK-PL
Y7002
3" NPT
7.4 (188)
8.9 (226)
14.3 (363)
4.17.2 INTERFACE ENCLOSURE MOUNTING
The interface box should be mounted at a location to allow all factory-supplied cables to reach and connect. The enclosure is
designed to be surface mounted and the size is 5 3/4” x 8 3/4” (146 x 222mm). Height of enclosure is 2 1/4” (57mm). Clearance is
needed for the cables that extend from one side. Refer to Figure 4.13.1 for hole layout.
4.17.3 ELECTRICAL WIRING
Each valve interface box is equipped with several connection points. A receptacle is built-in for connection to a joystick operator
station. A 4-pin plug is available for connection to a TFT RC monitor, typically a RC Tornado. A 2-pin plug (standard valve kit) or a
6-pin plug (gateable valve kit) is available for control of a valve. These two cables should be routed to the appropriate device and
plugged into the mating receptacle. The power cable should be routed to the truck’s power distribution center and connected to a
protected circuit. Refer to Figure 4.17.3 for typical connections.
The 2 ½” and 3” valve actuators also require a separate connection to a protected circuit. These valves are shipped with an additional
cable that includes a receptacle for connection to the valve actuator for power.