4.1 MONITOR MOUNTED
OPERATOR STATION
This operator station is factory installed and wired to the monitor. It allows the monitor to be controlled at the monitor location.
4.1.1 MOUNTING
Operator station is factory installed on the monitor and requires no additional mounting.
4.1.2 ELECTRICAL WIRING
See fi g. 4.0 for typical connections. The wiring on the monitor and for this operator station is factory installed. The assembly is
supplied with a cable for connection to the other operator control stations. The cable has 4-conductors which supply power and the
communications from the operator stations to the monitor.
4.1.3 CONNECTING DIRECTLY TO PROTECTED POWER SUPPLY
The electric RC monitor has an operator station, which is fully functional, mounted on the monitor. If no other operator stations are
selected, with the exception of the wireless radio remote, the installer will only need to connect power to complete the installation.
Route cable from monitor and connect to a protected circuit from the truck’s power distribution center. Connect the red wire to positive
and the black wire to negative (ground). Cut and discard blue and white wires.
4.1.4 OPERATION
This operator station is factory installed on the monitor and is used by personnel at the monitor.
OSCILLATE button used to
initiate monitor movement
through stored sequence
(pattern) or to program a
sequence (pattern).
Read manual before use.
WARNING
800-348-2686
Y5700
FLASHING = LOW BATT
®
ON
FLOW
OFF
OSCILLATE
PARK
UP
MONITOR
DOWN
www.tft.com
POWER
NO COMMUNICATION LINK
WHEN ALTERNATING
P
PARK button used to initiate
monitor storage sequence
or to program storage
movements.
FOG button used to move
nozzle pattern to wide and
short reach.
STRAIGHT STREAM button
used to move nozzle pattern
to narrow and long reach.
LEFT button used to rotate
(sweep) water stream from
right to left from starting
point.
UP button used to move
water stream vertically up
from starting point.
DOWN button used
to move water stream
vertically down from
starting point.
RIGHT button used to rotate
(sweep) water stream from
left to right from starting
position.
MONITOR UP/DOWN
button typically used to
control RC Extend-AGun.
Also known as the AUX1
button. Could also be used
with YE-REMAUX relay
interface box to control
other devices.
FLOW ON/OFF button
typically used to control
RC Valve Kit or VUM. Also
known as the AUX2 button.
Could also be used with YE-
REMAUX relay interface box
to control other devices.
Fig. 4.1.4
Operator Station Control Pad
4.1.5 BUTTON OVERLAY
Each monitor and operator station is shipped with several button overlays with adhesive that can be used to cover the button text
on the lower two buttons. This can be done in applications that do not have either an RC Extend-A-Gun or RC valve kit. If additional
overlays are needed, contact the factory.
Clean operator station surface to remove any oils or residues. Carefully peel off overlay and place on top of AUX button, just inside
blue border of the button.