©Copyright Task Force Tips, Inc. 2008-2014
LIY-500 May 12, 2014 Rev10
33
4.8.2.1 PROPORTIONAL SPEED CONTROL
Joystick operator stations that have the proportional speed control feature enabled are able to vary the rotational (horizontal) and up/
down (vertical) speed at which the monitor travels. The further the joystick is moved in any direction, the faster the monitor moves in
that direction. See section 4.8.3 for board confi guration
4.8.2.2 MONITOR DEPLOY FEATURE
Joystick operator stations that have the deploy feature enabled will be able to move the RC monitor to a predetermined position
with the press of a single button, refer to section 3.2.10. Button is located on lower right side of joystick. See section 4.8.3 for board
confi guration. Overlay labels are supplied with each monitor and can be applied to the buttons, refer to section 4.1.5.
4.8.2.3 RC EXTEND-A-GUN CONTROL
Joystick operator stations that have the RC Extend-A-Gun control enabled will be able to extend or retract the RC Extend-A-Gun
with the press of a single button. Button is located on upper right side of joystick. See section 4.8.3 for board confi guration. Overlay
labels are supplied with each monitor and can be applied to the buttons, refer to section 4.1.5.
4.8.3 JOYSTICK BOARD CONFIGURATION
To change the confi guration:
1. Ensure power is OFF to the unit.
2. Remove lid from enclosure.
3. Locate DIP switches on board and select confi guration based on Figure 4.8.3.
4. Verify seal area is clean and undamaged. Verify that no wires are caught between lid and box. Replace lid.
RC EXTEND-A-GUN
CONTROL ENABLED
DEPLOY FEATURE
ENABLED
PROPORTIONAL SPEED
CONTROL ENABLED
Figure 4.8.3
Board Confi guration
4.8.4 GATEABLE VALVE CONTROL
Valve control is combined between the sliding valve
position control lever along with the toggle switch
and joystick trigger. When the lever is at the bottom,
the valve opens just enough to have a usable water
stream. As the lever is moved towards the top the
amount of water fl ow is increased. When the lever
is all the way at the top, the valve is fully open. The
valve position LEDs located around the valve position
control lever indicate the actual position of the valve
as received from the valve interface box.
OPEN
TRIGGER CONTROL
VALVE CLOSED
OSC
PARK
800-348-2686
www.tft.com
®
MIN
FLOW
MAX
FLOW
VA
LV
E
Valve position
control lever
Valve closed
indication LED
Valve full open
indication LED
Valve intermediate
position and OPEN
travel direction
indication LED
Valve intermediate
position and CLOSE
travel direction
indication LED
Figure 4.8.4