For correct operation, check the battery voltage with the motorcycle turned off. If the battery is less than 12V, please 
recharge or replace it. Make sure that the battery is charging with the motorcycle on.

Auxiliary Output

8 and  9 - Green / Black

Dedicated Siren

+ 12 Vcc

Turning Signal

11 - Red

12 - Gray

10 - Gray

6 - 

Gray

5 - Orange/ Black

4 - Orange

Programming
press to GND

3 - Black

GND

2 - Blue

    Ignition

1 - Green

ENGINE BLOCK

MAX. 20A

7 - Black/ Yellow

According to Configuration:

1- Trunk/Trunk Button

2- High Beam Signal to activate 
the GATE - only in the TMA30

3- Gearbox NEUTRAL sensor.

According to Configuration:

1- Secret Button

2- Auxiliary 2 PULSE

3- Auxiliary 2 HOLD

- IT IS NECESSARY TO ACTIVATE THE AUTOMATIC  TRANSMISSION  OF THE   TR2-P CONTROL

- In the TMA G4 line, the standard configuration of the assault by presence mode is ENABLED, and it can be 
CANCELED in Beep 5 of the configuration.

- To prevent false triggers due to the inclination sensor, the alarm central must be well fixed, through the 
double-sided tape.

Attention:

Alarm basic operation:

 When activated by remote control, 

the  control  unit  records  the  inclination  of  the  motorcycle. 
Another 10 seconds, changing the inclination or turning on 
the ignition triggers the alarm.

10) Installation Scheme

09

Summary of Contents for Tarsafe TMA 10 G4

Page 1: ...MANUAL MOTORCYCLE ALARM TMA 10 TMA 20 TMA 30 ...

Page 2: ...lated to the desiredsetting Ateachtouch thealarmconfirmswith1beep Afterturningoff theignition beepsconfirmthenewsetting The installation of the product must be carried out by a qualified professional For its perfect operation the 12V signal with ignition on needs to be connected to the alarm This product is only intended to prevent or inhibit motorcycle theft Place the alarm central away from metal pa...

Page 3: ...ttery 3V CR 2032 LITHIUM Illustrative images and may be different from the real one See item 18 which remote control belongs to which model of the Alarm Anycontrolmodelcanbepurchasedseparately This equipment operaters in a secondary mode that is it does not have the right to protection against harmful interference even from stationsofthesametype anditcannotcauseinterferenceinsystems thatworkinaprim...

Page 4: ... Automatic Presence Transmission See item7 1 OnlyfortheTR2 Pcontrol Press for 2 seconds OnlyfortheTR2 Pcontrol Seeitem7 2 Press for 2 seconds 13 Range test presence function Cancel siren and lights The alarm remains activated Press with the alarm triggered 7 Cancel Trigger 4 Disable alarm without beep Press then 2 lightsFlashes Note 4flashesinthelights 4beeps indicatethat a alarm triggering has occ...

Page 5: ...ulse 3 beeps AUXILIARY 2 Output Retention 3 LONG BEEPS END OF PROGRAMMING WITHOUT CHANGING THE SETTINGS 16 FACTORY RESET 1 beep LONG factory settings restored 1 ENABLE DISABLE the alarm 1 beep ENABLE 2 beeps DISABLE 14 GREEN WIRE Setting See Item 11 1 1 beep trunk button 2 beeps HIGH BEAM signal 3 beeps gearshift neutral 3 12 Adjust SENSITIVITY INCLINATION Sensor To change see item 2 10 Motorcycle...

Page 6: ...BL wire on GND until beep 5 The alarm will sound with the current setting To change place the OR BLK wire on the GND the number of times related to the desired configuration At each touch the alarm confirms with 1 beep After turning off the ignition beepsconfirmthenewsetting To change place the OR BL wire on the GND the number of times related to the desired configuration At each touch the alarm confirm...

Page 7: ...t deactivate the automatic transmission of the TR2 Pcontrol turnontheignitionandwaitfortheprogrammedtime beep9 Howit works ItisusedtotesttherangeoftheautomatictransmissioninPresenceassaultmode With the automatic transmission activated on the control the function activated on the alarm control panel and the ignitionoff press the DISABLE and AUXILIARY buttonson theTR2P control until the LED turns off ...

Page 8: ...ter the programmed time according to the Beep 9 setting it triggers the siren and turn signals another 10 seconds the engine starts to stopuntilitturnsoff Tocanceltheblocking presstheSECRETBUTTON ATTENTION ThecontroldoesnotcanceltheassaultmodebySECRETBUTTON Enable Assault Mode by Secret Button 2Beeps DISABLE Turn on the ignition 1Beep ENABLE The alarm will sound with the current setting Put the OR ...

Page 9: ...no triggering limitation 9 1 SHUTDOWN TRIGGERING LIMITATION In the event of an alarm triggering the alarm activates the SIREN and the light flashes for 45 seconds Another 5 seconds check the sensors again Four triggerings from the same sensor cancel it keeping the others active The sensor will be activated the next time the alarm is activated by the remote control 9 3 1HOWTODEACTIVATETHEALARMINSAVI...

Page 10: ... Configuration 1 Trunk Trunk Button 2 High Beam Signal to activate the GATE only in the TMA30 3 Gearbox NEUTRAL sensor According to Configuration 1 Secret Button 2 Auxiliary 2 PULSE 3 Auxiliary 2 HOLD ITISNECESSARYTOACTIVATETHEAUTOMATIC TRANSMISSION OFTHE TR2 PCONTROL IntheTMAG4line thestandardconfigurationoftheassaultbypresencemodeisENABLED anditcanbe CANCELEDinBeep5oftheconfiguration To prevent fals...

Page 11: ...Control 3 Beeps Gearshift Neutral Sensor Turn on the ignition 2 Beeps High Beam Signal to activate gate Put the OR BLK wire on GND until beep 14 The alarm will sound according to the current setting Programming 1 Beep Trunk Button To change place the OR BL wire onthe GND the number of times related to the desired configuration Ateachtouch thealarm confirmswith1beep Afterturning offtheignition beepsco...

Page 12: ...ndwhenthebuttonisreleased itdeactivates 3 AUXILIARY2output retention Toturnofftheoutput presstheremote sOFFbuttonagain OperationExample Tostartthemotorcycle connecttheORANGEwiretotherelaytoturnontheignitionandtheGRAYwiretotherelayfor thestartbutton PresstheOFFbuttononthecontroluntiltheignitionison andpresstheAUXbuttonuntiltheenginestarts SincetheORANGEwire Auxiliary2output isinholdmode theignitionr...

Page 13: ...nddigit Standardpassword_3_ _3_NEWPASSWORD____ ____ 1 Turnontheignition 3 Whenreleasingthealarm itsounds4beepsandtheturningsignalswillremainon 4 Turnthecontactonandoffaccordingtothefirstdigit After a few seconds a long beep confirms that the new password has been entered If there are 2 beeps there was a recordingerror youhavetodothewholeprocessalloveragain 2 touchtheOR BLwireonGNDuntilbeep4 7 Attheen...

Page 14: ...ive the automatic transmission of the control or press theDeactivatebuttononthecontrol 5thBeep Activatesthe alarm WithBEEPandtheTURN SIGNALS do not flash when the control is moved away and Deactivates the alarm With BEEP as soon as receiving the automatic transmission of the control or pressing the Deactivatebuttononthecontrol To change touch the OR BLK wire on he GND the number of times related to...

Page 15: ... TARAMPS with address at Abílio Daguano Street 274 Res Manoel Martins Alfredo Marcondes SP ZIP 19 180 000 warranties this product against eventual manufacturing defects or product component defects for a 24 month deadline from the date of thepurchase Productsdamagedbyimproperinstallationorinstallationbyunauthorizedindividuals Warranty Term TR2 P with presence function only TR2 TR5 TMA 10 G4 Contro...

Page 16: ...MN_016030_R01 ...

Reviews: