Page | 58
8.5.10
Event Codes
The OQDe will analyse the data received from the OQSxG2 Sensor and based on the initial
setup or amendments to the configurable parameters can provide a range of warnings or
alarms.
In addition to the warnings and alarms determining the colour of the oil status LED, the display
will also show an event code, identifying possible action required.
Event codes can also identify potential issues with sensor connection as well as potential sensor
and display configuration issues.
Figure 42 lists the available event codes.
Event
Code
Algorithm
Description
Check/
Alert
---
n/a
All OK
n/a
S01
n/a
No Sensor Connected
– Please Connect the Sensor.
A
S02
n/a
Sensor Not Configured
– Configure the Sensor via CADS.
A
S03
n/a
Display Not Configured
– Configure the Display via Insight
A
S04
n/a
New Sensor Detected
n/a
E01
Current Temperature >= Temp High Warning Level
Oil Temperature High
– Check Regularly.
C
E02
Current Temperature >= Temp High Alarm Level
Oil Temperature Very High
– Immediate Action Required.
A
E03
Current Temperature <= Temp Low Warning Level
Oil Temperature Low
– Check Regularly.
C
E04
Current Temperature <= Temp Low Alarm Level
Oil Temperature Very Low
– Immediate Action Required.
A
E05
Current Oil Condition >= Oil Condition High Warning Level
Oil Condition Too High
– Check Regularly.
C
E06
Current Oil Condition >= Oil Condition High Alarm Level
Oil Condition Very High
– Immediate Action Required.
A
E07
Current Oil Condition <= Oil Condition Low Warning Level
Oil Near End Of Life
– Check Regularly.
C
E08
Current Oil Condition <= Oil Condition Low Alarm Level
Oil At End Of Life
– Immediate Action Required.
A
E09
Current Oil Condition >= 1200 TDN
Sensor In Air
– Immediate Action Required
A
E11
Long Term +ve Decay Rate Warning (TDN/day)
Oil Quality degrading faster than expected
– Check
Regularly.
C
E12
Long Term +ve Decay Rate Alarm (TDN/day)
Oil Quality degrading much faster than expected
–
Immediate Action Required.
A
E13
Long Term -ve Decay Rate Warning (TDN/day)
Oil Quality improving faster than expected - Check
Regularly.
C
E14
Long Term -ve Decay Rate Alarm (TDN/day)
Oil Quality improving much faster than expected -
Immediate Action Required.
A
E15
Short Term +ve Decay Rate Warning (TDN/day)
Oil Quality degrading faster than expected - Possible
Water/Coolant Contamination - Check Regularly.
C
E16
Short Term +ve Decay Rate Alarm (TDN/day)
Oil Quality degrading much faster than expected
– Highly
Likely Water/Coolant Contamination - Immediate Action
Required.
A
E17
Short Term -ve Decay Rate Warning (TDN/day)
Oil Quality improved - Suspected oil top up / sweetening -
Check Regularly
C
E18
Short Term -ve Decay Rate Alarm (TDN/day)
Oil Quality improved too much - Suspected Air or severe
fluid contamination - Immediate Action Required.
A
Figure 42 - List of Event Codes
Summary of Contents for OQSExISG2
Page 1: ...UG OQSxG2 23 0025 OIL QUALITY SENSOR ASSOCIATED ACCESSORIES USER GUIDE...
Page 2: ......
Page 5: ...Page 3 Page Intentionally Blank...
Page 37: ...Page 35 Figure 19 Connection to other Tan Delta and 3rd Party Products Interfaces...
Page 38: ...Page 36 Figure 20 ExOQSxG2 Ex Sensor Installation Drawing Rev 2 STAMPED...
Page 42: ...Page 40 8 Display Express...