8.3
Installation
8.3.1
Mounting
The OQDe has a flange on either side with mounting holes to allow it to be fixed to any suitable
flat surface. Once your OQDe is correctly configured, you need to mount it using the flanges on
the sides.
Figure 39 - OQDe Mounting Dimensions
Please ensure that the following environmental specifications are not exceeded by the
proposed location.
Protection Rating:
IP67
Enclosure Type:
Rugged, polycarbonate machined housing with mounting
flanges
Temperature (Operating)
-30C to +65C
Temperature (Storage)
-30C to +70C
Pressure (Ambient)
1 bar +/- 150mbar
Chemical Exposure (Splash)
Water, Mineral and Synthetic Oils
8.3.2
Connection
8.3.2.1
Connecting the Oil Quality Sensor
Connect the Oil Quality Sensor (OQSxG2) to the left-hand connector on the OQDe using a
Cable
SD
(Sensor to Display Cable). 2m, 5m, 10m, 15m, 25m, 50m, & 100m lengths available as
standard. Align and slot in the 6-pin connector and then tighten the connector screw-cap.
Please refer to the OQSxG2 section of the manual for further information about OQSxG2 setup
and calibration.
Summary of Contents for OQSExISG2
Page 1: ...UG OQSxG2 23 0025 OIL QUALITY SENSOR ASSOCIATED ACCESSORIES USER GUIDE...
Page 2: ......
Page 5: ...Page 3 Page Intentionally Blank...
Page 37: ...Page 35 Figure 19 Connection to other Tan Delta and 3rd Party Products Interfaces...
Page 38: ...Page 36 Figure 20 ExOQSxG2 Ex Sensor Installation Drawing Rev 2 STAMPED...
Page 42: ...Page 40 8 Display Express...