Page | 18
6.1.1.5
Communications settings
This next screen lists the options for the device you wish to connect the sensor to:
Oil Quality Display Express
–
sets the sensor to use our proprietary RS485
communications protocol.
Oil Quality Telemetry Gateway
–
This sets the sensor to CANbus for use with our legacy
range of gateway devices operating on CANbus. Ensure sensors are uniquely numbered
from 1-10. (
NOTE:
The newer versions of the Gateway Device are supplied configured
for Modbus and therefore require Custom Communications Settings)
Custom Communications Settings
–
Allows you to select custom node ID and bit rate for
RS485, CANbus, J1939, Modbus.
Note: CANbus Self Starting allows the sensor to power up straight into Operational
mode and begin sending Process Data Object (PDO) responses without validation
from a CANopen master so the sensor can be used on systems without a full
CANopen master.
Note: If you are using the sensor with the OQTg, Node ID must be set uniquely to each
sensor, numbered 1-16.
Figure 6 - Communication Options