Cable Specification
RS-449 Cable to KIV-7
TANDBERG MXP and Classic Endpoints that support External
Network
•
Connector on Tandberg End:
o
Female 26pin High Density DSUB Newark P/N 50F2055 or Equivalent
•
Connector on RS-449:
o
DSUB 37 pin Male
Signal Name
Female
26pin DSUB
(Tandberg
end)
Pin Number
Male
37pin
DSUB
(DCE end)
Pin
Number
Comments
Frame Ground
1
1
Do not connect shield to
FGND
Send Data (A)
Send Data (B)
11
12
4
14
Twisted Pair
Send Timing (A)
Send Timing (B)
17
18
15
12
Twisted Pair
Receive Data (A)
Receive Data (B)
13
14
3
16
Twisted Pair
Receive
Timing(A)
Receive Timing
(B)
15
16
17
9
Twisted Pair
LOS
25
31
Signal Ground
19
1
4,20,28
19,23,27
Jumpers