Parameter group
Parameter
Description
I/O
Serial
Baud
Format
Baud = 600
Baud = 1200
Baud = 2400
Baud = 4800
Baud = 9600*
Baud = 19200
7 Bit No
2 Stop
7 Bit Even 1 Stop
7 Bit Odd
1 Stop
7 Bit Even 2 Stop
7 Bit Odd
2 Stop
7 Bit Mark 1 Stop
7 Bit Spc1 Stop
7 Bit Mark 2 Stop
7 Bit Spc2 Stop
8 Bit No
1 Stop*
8 Bit No
2 Stop
8 Bit Even 1 Stop
8 Bit Odd
1 Stop
8 Bit Mark 1 Stop
8 Bit Spc1 Stop
Selects the data transmission rate (baud rate; baud = bit per second).
Printer and computer must have the same baud rate.
1. Sets the number of data bits
2. The parity test for received data bytes can be selected. NO causes transmission in
both directions without parity bit. If EVEN or ODD is selected, the bytes are
checked if they have even or odd parity. The selection of MARK or SPACE causes
a data byte transmission with parity bit, but without checking the received data.
Transmission data with parity bit is always marked with 1 (MARK) or 0 (SPACE).
3. Selects one or two stop bits per data byte.
Special
ErrMode
Blockend
ErrMode = On
ErrMode = Off*
Blockend = On
Blockend = Off*
Only with serial interface and if the ENQ/STX, ETX/ACK or ACK/NAK protocol is set.
See Chapter
Interfaces
Error handling; On replaces the incorrect character with ?, Off deletes the entire
block.
End-of-block character definition: On = LF, FF, CR, VT, ETX, DEL, Off = ETX, DEL.
Reference manual
The Menu
74