TALARIA POWER TECH
Malfunction Inspection and Troubleshooting
43
02000 Motor lack of phase
1. Didn’t press the power button.
2. Motor phase wires (U/V/W) loose or incorrect connection.
1. Press the power button to restart your motorcycle.
2. Power off your motorcycle. Then, check the whether
the motor phase wire terminal got loose, or broken.
And then, check whether the motor outlet phase
sequence corresponds to the U / V / W on the
controller. Finally, check whether the magnetic
encoder output wire corresponds to the yellow, green
and blue wires on the harness assy.
If the error code still shows, send
the motorcycle to the nearest
dealer for service.
44
03000
Motor locked-rotor
protection error
If the rear wheel is stuck, and cannot rotate, or the motor, gearbox, brake,
chain is stuck, will cause the discharge current load to be equal or greater
than the protection setting. Then, cause the error.
1. Power off your motorcycle, put it on a stand, check
whether the rear wheel can rotate normally, if anything
stuck the rear wheel, please eliminate it. And please
also check whether there’re things stuck the motor,
gearbox, chain and brake. If yes, please eliminate it.
2. Choose the right ground to ride your motorcycle.
If the error code still shows, send
the motorcycle to the nearest
dealer for service.
45
04000 Communication error
CAN communication wire loose, fall off or hardware failure.
Power off your motorcycle, check all the CAN
connections on your motorcycle to see whether there’s
the loose or damages (Dash connection, controller
connection, battery communication connection. These
3 positions have CAN connections). If there’s the loose
or damages, just repair them, and re-start your
motorcycle, the error will be
solved.
If the error code still shows, send
the motorcycle to the nearest
dealer for service.
Summary of Contents for STING R L1E
Page 1: ...TALARIA POWER TECH STING R L1E OWNER S MANUAL...
Page 8: ...TALARIA POWER TECH General Information Vehicle Overall Dimension...
Page 9: ...TALARIA POWER TECH General Information Circuit Schematic Diagram...
Page 12: ...TALARIA POWER TECH Safety Information Location of Important Labels...
Page 15: ...TALARIA POWER TECH Controls and Components 1 1 2 3...