TALARIA POWER TECH
Malfunction Inspection and Troubleshooting
20
00060
Battery discharging low
temperature
When the battery is discharging, if the temperature is too low, the battery will
carry out the low temperature protection function.
Stop riding your motorcycle until the low temperature
protection unlocked.
It’s strongly suggested to follow
this owner’s manual to use your
motorcycle.
21
00070
Battery charging low
temperature
When the battery is charging, if the temperature is too low, the battery will
carry out the low temperature protection function.
Stop charging the battery until the low temperature
protection unlocked.
It’s strongly suggested to follow
this owner’s manual to use your
motorcycle.
22
00080
Discharging MOS
overtemperature
MOS overtemperature which is caused by battery discharging.
Stop riding your motorcycle until the overtemperature
protection unlocked.
It’s strongly suggested to follow
this owner’s manual to use your
motorcycle.
23
00090
Charging MOS
overtemperature
MOS overtemperature which is caused by battery charging.
Stop charging the battery until the overtemperature
protection unlocked.
It’s strongly suggested to follow
this owner’s manual to use your
motorcycle.
24
000A0
Soft-start circuit
overtemperature
If the temperature is high when use the soft-start, will cause the
discharging MOS not work, and lead the entire soft-start circuit
to be overtemperature.
Stop riding your motorcycle until the overtemperature
protection unlocked.
25
000B0 Storage error
It’s caused by the faulty operation during the production.
Send your motorcycle to the nearest dealer to repair.
26
000E0 Level 3 over current error
Short circuit in the external circuit causes this error.
Inspect and eliminate the short circuit.
If the error code still shows, send
the motorcycle to the nearest
dealer for service.
27
000F0 Level 4 over current error
28
00100 Setting error
It’s caused by the faulty operation during the production.
Send your motorcycle to the nearest dealer to repair.
29
00300
Controller phase wire
over current
Controller phase wire current is equal or greater than the protection setting.
32.
Power off your motorcycle, check the whether the
motor phase wire terminal got loose, or broken.
And then, check whether the motor outlet phase
sequence
corresponds to the U / V / W on the controller. Finally,
check whether the magnetic encoder output wire
corresponds to the yellow, green and blue wires on
the harness assy.
2. Check whether anything stuck the rear wheel.
If the error code still shows,
replace the magnetic encoder or
send the motorcycle to the
nearest dealer for service.
30
00400
Controller busbar over
current error
Controller busbar current is equal or greater than the protection setting.
32.
Power off your motorcycle, check the whether the
motor phase wire terminal got loose, or broken.
And then, check whether the motor outlet phase
sequence
corresponds to the U / V / W on the controller. Finally,
check whether the magnetic encoder output wire
corresponds to the yellow, green and blue wires on
the harness assy.
2. Check whether anything stuck the rear wheel.
If the error code still shows,
replace the magnetic encoder or
send the motorcycle to the
nearest dealer for service.
31
00500 Controller MOS error
Controller MOS welding loose or MOS is broken.
Replace the controller or send the motorcycle to the
nearest dealer for service.
Summary of Contents for STING R L1E
Page 1: ...TALARIA POWER TECH STING R L1E OWNER S MANUAL...
Page 8: ...TALARIA POWER TECH General Information Vehicle Overall Dimension...
Page 9: ...TALARIA POWER TECH General Information Circuit Schematic Diagram...
Page 12: ...TALARIA POWER TECH Safety Information Location of Important Labels...
Page 15: ...TALARIA POWER TECH Controls and Components 1 1 2 3...