background image

After installation

Caution

Be sure to execute the inspection without fail to prevent accidents during operation.

Inspection

Inspect the following items.

(1) Check that there are no missing screws or other parts.

(2) Check that there are no loose parts on the shampoo unit or the chair. If any part of the shampoo unit or the chair is 

        loose, check the bolts at the joints again.

(3) Check that there are no cracks or contamination on the basin.

(4) Check that there are no problems, such as scratches on the external appearance.

(5) Check that there are no water leaks on the floor.

(1) Set the neck cushion to the metal fittings in the 

        direction as shown in the image.

(3) Adjust the shape of the neck cushion to suit the metal fittings, 

       and attach the basin side snap buttons of the neck cushion to the 

       fastening pins.

Insert the head pillow in the direction as shown in the image.

(2) Attach the seat side snap buttons of the neck cushion to the 

        fastening pins on the metal fittings.

The fastening pins can be removed.

Take care not to lose the fastening pins.

15

Attach neck cushion

Attach head pillow

Neck 

cushion

Snap button

Basin side

Seat side

The short edge 

faces basin side

The long edge 

faces seat side

Metal fittings

Fastening pin

Snap button

Snap button

Head pillow

(underside)

Attachment fitting

Summary of Contents for YUME NAGOMI

Page 1: ...are to ensure that YUME NAGOMI can be installed safely and to prevent any danger or risk to the person installing YUME NAGOMI or those around them All of these precautions are important for safety Tak...

Page 2: ...t water pipes and water supply pipes Always use a reamer to deburr the ends of cut pipes Avoid using inverted U shaped pipes siphon as these can cause air to become trapped Always connect hot water pi...

Page 3: ...tains rust or sand If the water hardness is 80 ppm or higher install a water softener to prevent the buildup of scale within the basin body Aeration may be minimal when using shampoo even if drinkable...

Page 4: ...rain hose gasket Pipe gasket Water stop valve 2 L 200mm Footrest Footrest low H type L type Maintenance Cover small Base cover Trap cover Head pillow Mohair tape Maintenance Cover Installation instruc...

Page 5: ...unit base four locations Detach the basin unit from the skid Carrying the Basin Unit 1 Carrying the main body Attach the carriage jig to the seat frame with bolts 2 locations 2 Attach the carriage ji...

Page 6: ...basin Do not hold the main body cover Doing so may cause damage to the main body cover Take care when handling the basin as it is heavy and fragile Do not drag the unit The foot part of the basin is...

Page 7: ...event water leakage under the floor and downstairs Be sure to take the necessary precautions to prepare for and prevent possible water leaks Use waterproof flooring materials If the floor has an openi...

Page 8: ...mage the drain hose Check that the drain hose clamp is firmly fastened If it is not fastened water may leak or the drain hose may come loose Check of no double trap An Double trap can adversely affect...

Page 9: ...thin the check valve and sprinkling filter unit Failure to do so can result in insufficient flow rate and faulty temperature regulation Cleaning How to adjust faulty temperature regulation 3 Test wate...

Page 10: ...Caution Attach the two locations on the top of the footrest slide rail to the basin unit using truss head screws M6 x 15 2 screws Assemble while the footrest is retracted packing state Tighten the sc...

Page 11: ...footrest is installed while it is slided out this could lead to the footrest rattling poor sliding operation and noise Ensure the footrest is installed while fully retracted Fully tighten the truss he...

Page 12: ...h the leg rest using hexagonal head bolts M6 x 15 2 bolts Velcro Back support cusion Velcro Screen sheet 3 Attaching the Seat Part Attach the legrest Attach the edge of seat to the legrest by velcro 4...

Page 13: ...Black 6screws Remove the maintenance cover and the base cover Maintenance cover Base cover Check that pressing the reclining pedal with your foot reclines the backrest and lifting your foot off the r...

Page 14: ...s in as a fulcrum while pushing both edges inwards Position the screw sections so they pass through the trap cover attachment holes and when the screws emerge from below fix with urea cosmetic nuts Pu...

Page 15: ...water leaks on the floor 1 Set the neck cushion to the metal fittings in the direction as shown in the image 3 Adjust the shape of the neck cushion to suit the metal fittings and attach the basin side...

Page 16: ...ot water supply position Water supply position Drain position Wall surface or furniture Wall surface or furniture Footrest front back slide Figures shown above are for seating a customer about 170cm i...

Page 17: ...ile or glass surface within 2 or 3 mm Show the floor installation surface Caution for Anchor Bolt Installation Anchor bolts should be installed so that the screws will protrude from the bolt head by 3...

Page 18: ...MEMO 18...

Page 19: ...MEMO 19...

Page 20: ...20 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan TEL 81 6 6213 5945 FAX 81 6 6212 3680 TAKARA BELMONT CORPORATION Printed in Japan 1E03U3B0...

Reviews: