background image

Contents of defect

   

Something wrong with hot water (Temperature is unstable) 

   

Hot water (high temperature) does not come out

   

Water (low temperature) does not come out

Presumed cause 

   

There is difference in the water supply and hot-water supply pressure, 

       or the pressure of hot water supply is higher than the pressure of water supply.

       [ The pressure of water supply 

 the pressure of hot water supply 

        (The difference should be in the range of 0.2Mpa) ]
   

Pressure of water supply and hot water supply is high

       [ These two should be in the range between 0.1 and 0.4MPa ]

How to remedy the defect

   

Connect a pressure reducing valve (Optional) on the upper side (mixer side) 

   of the filtered check valve, then adjust the pressure.

  (It is recommended that water supply pressure and hot water supply pressure become the same pressure) 

Filtered check valve

Filter

Remove and clean any dirt 

trapped within the filter. 

Remove and clean any dirt trapped within the shower head plate

.

Sprinkling filter unit

Shower head main unit

Gasket

Foaming water outlet

O-ring

 After the hot water becomes clear during the water flow test, always clean the filter (within the check valve) 

and  sprinkling filter unit.

Failure to do so can result in insufficient flow rate and faulty temperature regulation.

Cleaning

How to adjust faulty temperature regulation

3 Test water flow

Caution

Always test the water flow to prevent 

accidents during use.

Shower outlet flow rate

* Test the water flow and inspect the following 

items. The hot water may be slightly tainted at 

the start of the water flow test,however this 

does not indicate any problem.

* For safety reasons, the product's thermostat is 

designed so that the hot water does not 

exceed 53°C.

(if the supply pressure is the same, water 

temperature is 20°C and hot water 

temperature is 60°C)

(1)Is there no water leaking from the pipe joints?

The pipe joints may come loose during transportation, 

so check the joints within the basin thoroughly.

(2)Are the hot water supply and water supply pressures at 

the same, stable pressure?

If the pressure is not the same, see "How to adjust 

faulty temperature regulation" below.

(3)Can temperature be controlled properly?
(4)Check that the shower outlet flow is sufficient, by the 

following as a guide for flow rate.

Spa shower head

      (Low splash foaming mode) : Approximately 6.4 L/min

                                 (Shower mode) : Approximately 9.9 L/min

9

Hot water supply pressure, water supply pressure:0.1MPa each

Shower outlet temperature:40°C

Summary of Contents for YUME NAGOMI

Page 1: ...are to ensure that YUME NAGOMI can be installed safely and to prevent any danger or risk to the person installing YUME NAGOMI or those around them All of these precautions are important for safety Tak...

Page 2: ...t water pipes and water supply pipes Always use a reamer to deburr the ends of cut pipes Avoid using inverted U shaped pipes siphon as these can cause air to become trapped Always connect hot water pi...

Page 3: ...tains rust or sand If the water hardness is 80 ppm or higher install a water softener to prevent the buildup of scale within the basin body Aeration may be minimal when using shampoo even if drinkable...

Page 4: ...rain hose gasket Pipe gasket Water stop valve 2 L 200mm Footrest Footrest low H type L type Maintenance Cover small Base cover Trap cover Head pillow Mohair tape Maintenance Cover Installation instruc...

Page 5: ...unit base four locations Detach the basin unit from the skid Carrying the Basin Unit 1 Carrying the main body Attach the carriage jig to the seat frame with bolts 2 locations 2 Attach the carriage ji...

Page 6: ...basin Do not hold the main body cover Doing so may cause damage to the main body cover Take care when handling the basin as it is heavy and fragile Do not drag the unit The foot part of the basin is...

Page 7: ...event water leakage under the floor and downstairs Be sure to take the necessary precautions to prepare for and prevent possible water leaks Use waterproof flooring materials If the floor has an openi...

Page 8: ...mage the drain hose Check that the drain hose clamp is firmly fastened If it is not fastened water may leak or the drain hose may come loose Check of no double trap An Double trap can adversely affect...

Page 9: ...thin the check valve and sprinkling filter unit Failure to do so can result in insufficient flow rate and faulty temperature regulation Cleaning How to adjust faulty temperature regulation 3 Test wate...

Page 10: ...Caution Attach the two locations on the top of the footrest slide rail to the basin unit using truss head screws M6 x 15 2 screws Assemble while the footrest is retracted packing state Tighten the sc...

Page 11: ...footrest is installed while it is slided out this could lead to the footrest rattling poor sliding operation and noise Ensure the footrest is installed while fully retracted Fully tighten the truss he...

Page 12: ...h the leg rest using hexagonal head bolts M6 x 15 2 bolts Velcro Back support cusion Velcro Screen sheet 3 Attaching the Seat Part Attach the legrest Attach the edge of seat to the legrest by velcro 4...

Page 13: ...Black 6screws Remove the maintenance cover and the base cover Maintenance cover Base cover Check that pressing the reclining pedal with your foot reclines the backrest and lifting your foot off the r...

Page 14: ...s in as a fulcrum while pushing both edges inwards Position the screw sections so they pass through the trap cover attachment holes and when the screws emerge from below fix with urea cosmetic nuts Pu...

Page 15: ...water leaks on the floor 1 Set the neck cushion to the metal fittings in the direction as shown in the image 3 Adjust the shape of the neck cushion to suit the metal fittings and attach the basin side...

Page 16: ...ot water supply position Water supply position Drain position Wall surface or furniture Wall surface or furniture Footrest front back slide Figures shown above are for seating a customer about 170cm i...

Page 17: ...ile or glass surface within 2 or 3 mm Show the floor installation surface Caution for Anchor Bolt Installation Anchor bolts should be installed so that the screws will protrude from the bolt head by 3...

Page 18: ...MEMO 18...

Page 19: ...MEMO 19...

Page 20: ...20 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan TEL 81 6 6213 5945 FAX 81 6 6212 3680 TAKARA BELMONT CORPORATION Printed in Japan 1E03U3B0...