Request measures to prevent water leakage under the floor and downstairs 

Use waterproof flooring materials.

If the floor has an opening, cover the opening when completing the interior finishing (waterproofing).

Install all pipe gaskets.

Before installation

Installation of pipes

The following are important points to adhere during the installation of pipes.

Read through the details carefully and ensure that the pipes are installed correctly.

When installing this product, ensure that installation of pipes adheres to the instructions outlined in "Precautions during 

installation of pipes". Installing pipes without reading through the precautions will mean water may not mix properly, and 

a set temperature will not be achieved.

This product is designed for indoor installation. Always install this product indoors.

Precautions during installation of pipes

Do not use pipes made of materials that may introduce rust for the water supply pipe.

In general, VP pipes or other materials specified by regulations in that particular region, are recommended for installation.

In general, Type L deoxidized copper pipes are recommended for hot water pipes.

In general, the same diameter and same pressure is recommended for hot water pipes and water supply pipes.

Always use a reamer to deburr the ends of cut pipes.

Avoid using inverted U-shaped pipes (siphon) as these can cause air to become trapped.

Always connect hot water pipes and water supply pipes after removing all contaminants such as dirt, sand and oil as 

these can cause problems.

After connecting the pipes and testing water flow, clean the filter and shower head.

Ensure that the drain pipe is installed at a gradient of 1/50  or more for a diameter of ∅75 or less, or 1/100 or more for  

a diameter of ∅75 or more.  

Do not connect the hot water pipes and water supply pipes in reverse. 

Connecting pipes in reverse will mean the temperature of water cannot be controlled properly by the water taps, which can 

cause problems including burns.

Ensure that the hot water pipes from water boilers are only run over a short distance so as to minimize resistance. 

Longer pipes can cause fluctuations in temperature and poor hot water delivery.

Always wrap pipes with lagging material after installation is complete.

Water boiler pipes

 • In general, the same diameter and same pressure is recommended for main hot water pipes and main water supply pipes.
 • Ask professional to install water boiler.

Equipment comes with hair catchers installed.

Avoid the anchor positions when installing the pipe risers.

Be sure to take the necessary precautions to prepare for and prevent possible water leaks.

2

Summary of Contents for YUME NAGOMI

Page 1: ...are to ensure that YUME NAGOMI can be installed safely and to prevent any danger or risk to the person installing YUME NAGOMI or those around them All of these precautions are important for safety Tak...

Page 2: ...t water pipes and water supply pipes Always use a reamer to deburr the ends of cut pipes Avoid using inverted U shaped pipes siphon as these can cause air to become trapped Always connect hot water pi...

Page 3: ...tains rust or sand If the water hardness is 80 ppm or higher install a water softener to prevent the buildup of scale within the basin body Aeration may be minimal when using shampoo even if drinkable...

Page 4: ...rain hose gasket Pipe gasket Water stop valve 2 L 200mm Footrest Footrest low H type L type Maintenance Cover small Base cover Trap cover Head pillow Mohair tape Maintenance Cover Installation instruc...

Page 5: ...unit base four locations Detach the basin unit from the skid Carrying the Basin Unit 1 Carrying the main body Attach the carriage jig to the seat frame with bolts 2 locations 2 Attach the carriage ji...

Page 6: ...basin Do not hold the main body cover Doing so may cause damage to the main body cover Take care when handling the basin as it is heavy and fragile Do not drag the unit The foot part of the basin is...

Page 7: ...event water leakage under the floor and downstairs Be sure to take the necessary precautions to prepare for and prevent possible water leaks Use waterproof flooring materials If the floor has an openi...

Page 8: ...mage the drain hose Check that the drain hose clamp is firmly fastened If it is not fastened water may leak or the drain hose may come loose Check of no double trap An Double trap can adversely affect...

Page 9: ...thin the check valve and sprinkling filter unit Failure to do so can result in insufficient flow rate and faulty temperature regulation Cleaning How to adjust faulty temperature regulation 3 Test wate...

Page 10: ...Caution Attach the two locations on the top of the footrest slide rail to the basin unit using truss head screws M6 x 15 2 screws Assemble while the footrest is retracted packing state Tighten the sc...

Page 11: ...footrest is installed while it is slided out this could lead to the footrest rattling poor sliding operation and noise Ensure the footrest is installed while fully retracted Fully tighten the truss he...

Page 12: ...h the leg rest using hexagonal head bolts M6 x 15 2 bolts Velcro Back support cusion Velcro Screen sheet 3 Attaching the Seat Part Attach the legrest Attach the edge of seat to the legrest by velcro 4...

Page 13: ...Black 6screws Remove the maintenance cover and the base cover Maintenance cover Base cover Check that pressing the reclining pedal with your foot reclines the backrest and lifting your foot off the r...

Page 14: ...s in as a fulcrum while pushing both edges inwards Position the screw sections so they pass through the trap cover attachment holes and when the screws emerge from below fix with urea cosmetic nuts Pu...

Page 15: ...water leaks on the floor 1 Set the neck cushion to the metal fittings in the direction as shown in the image 3 Adjust the shape of the neck cushion to suit the metal fittings and attach the basin side...

Page 16: ...ot water supply position Water supply position Drain position Wall surface or furniture Wall surface or furniture Footrest front back slide Figures shown above are for seating a customer about 170cm i...

Page 17: ...ile or glass surface within 2 or 3 mm Show the floor installation surface Caution for Anchor Bolt Installation Anchor bolts should be installed so that the screws will protrude from the bolt head by 3...

Page 18: ...MEMO 18...