T r o u b l e s h o o t i n g
18
When a problem cannot be rectified even if an inspection is made according to the table shown below, immediately
stop using the product, turn off the power switch, disconnect the power plug, and immediately contact the nearest
dealer or Takara Belmont directly.
Check if the customer's head position is not
set too far away from the correct position.
(See page 11.)
If the error code appears continuously even
where the customer s head set in the correct
position, turn off the power and contact the
nearest dealer or Takara Belmont directly.
Check if the customer's head position is not
set too far away from the correct position.
(See page 12.)
If the error code appears continuously even
where the customer s head set in the correct
position, turn off the power and contact the
nearest dealer or Takara Belmont directly.
Check if the ring does not interrupt wall or
other equipment.
Move the product to the position where
the ring does not contact with wall or other
equipment, and turn off, then turn on the
power. If the above‑stated action does not
rectify the symptom, turn off the power and
contact the nearest dealer or Takara
Belmont directly.
Phenomenon
Check Point
Countermeasures
The error
illuminates.
The error
illuminates.
The error
illuminates.
The error
illuminates.
Check if the Roller Ball is set in the correct
position properly.
When the customer s head may be set too
far from the correct position, the infrared
thermal sensor detects heat from a
surrounding heater and so on, leading to
the error.
Turn on the power after setting the product
in the correct position. If this does not
rectify the symptom, turn off the power and
contact the nearest dealer or Takara
Belmont directly.