background image

15

1

2

温度レベル、時間、加温ポジションの設定変更

設定内容を変更する場合は、お客様の毛髪の状態、使用する薬剤、施術内容に応じて変更して下さい。

●温度レベルの変更は温度レベルボタンで変更します。
●タイマー表示部が時間表示の時は時間設定キーで時間を変更します。また同様に、角度表示の 時
も時間 設置キーで角度を変更します。角度表示は△▽ボタンを押すごとに次のように切り替わ り

4

4

加温ポジションの違いによる加温状態

標準位置

フロントOFF

サイドOFF

ネープOFF

全 加 温

ポジシ

ョン

本体位置

80mm
下げ た

加温部

参  考

本体を標準位置より
80mm下げた場合

3

80mm

Rotation and Stopping of Ring during Operation

Pa r t i a l   H e a t i n g

When either of the heating positions (FRONT, SIDE or NAPE) is turned off, the temperature 

control is subject to the ON/OFF control of heater according to the programmed time. 

The temperature control with the infrared thermal sensor will not be executed.

Set the Roller Ball in the correct position. 

If the unit is not set in the correct position, it will not work properly. (See page 11.)

Select a mode.

Press  the  operation  mode  selection  button  after  turning  on  the  power  switch.  At  this  time,  check  the 

temperature level and the time setting for the selected operation.

Press the Start/Stop button.

Press the Start/Stop button to rotate the ring under the selected conditions. 

Select a heating position.

Press a partial heating button (FRONT, SIDE or NAPE).

*The heater of the rotating ring can be set to OFF only when it passes the designated part.

Only for the Manual Mode

O p e r a t i o n

During operation

When the operation
is interrupted

When the operation
is resumed in five
minutes after interruption

During cooling time

After cooling time

S t a t e   o f   R i n g   R o t a t i o n   B u t t o n   d u r i n g   Op e r a ti o n

For regular use

(Ring rotation button: ON)

For use where the ring rotation is 
stopped under the manual mode
(Ring Rotation button: OFF)

The ring rotates.
The heater is ON.

The ring stops at the position 
when the button is pressed.
The heater is OFF.
The ring starts to rotate.
The heater is ON.

The ring rotates.
The heater is OFF.

The ring rotates to the home 
position and stops there.
The heater remains to be OFF.

The ring stops at the position of 
the manual mode stop.
The heater is ON.
The ring remains in the stop state.
The heater is OFF.

The ring remains in the stop state.
The heater is ON.

*The cooling time is not provided
  for the fixed operation under the 
  manual mode.

Summary of Contents for Roller Ball AK-S23A

Page 1: ...dure Information Dimensions and Specifications Lamp Indication during Operation and Inputs from Button Customized Settings Safety Precautions To be strictly observed Name of Each Part Thank you for pu...

Page 2: ...tes enforcement or instructions for general user behavior Indicates the prohibition of disassembly repair or modification Indicates the need for paying attention to high temperatures Indicates the pro...

Page 3: ...r to contact the heater guard while the customer dozes during operation or after using the Roller Ball Neglecting this warning may result in a burn injuries Do not suspend anything from the product or...

Page 4: ...g operation or right after the use Do not touch the ring including the ring heater heater guard reflector etc during operation or right after the use of the Roller Ball Neglecting this caution may res...

Page 5: ...red rays the infrared thermal sensor can correctly measure the hair temperature thereby enabling correct temperature control Do not allow the chemicals to adhere to the heater Use the product while pa...

Page 6: ...5 Guide Bar Nape Guard Heater Guard Power Switch Fuse Control Panel Reflector Ring Heater Infrared Thermal Sensor Top Cover Sensor Sheet Ring Cover Upper Shaft Grip Specification with Fan Shaft Cover...

Page 7: ...6 15P Operating Manual 1 copy MAY CAUSE BURNS DO NOT TOUCH THE HEATER GUARD MAY CAUSE THE DAMAGE ON THE HEATER DO NOT GIVE AN EXCESSIVE SHOCK TO THE RING Accessories Location of Warning Label...

Page 8: ...setting Each press of the UP or the DOWN button changes the temperature level by one step The level can be set in seven steps Each press of the UP or the DOWN button changes the time in units of a min...

Page 9: ...ng Rotation Button and Lamp Mute Button and Lamp Fan Button and Lamp Only for the specification with fan Lamp Lamp Lamp Use the button to stop or rotate the ring at a desired position Only for the man...

Page 10: ...emperature Control System Temp Level Time Heating Position Temperature control by infrared thermal sensor Temperature level and temperature settings Heating position Rotation Hot double process perms...

Page 11: ...ead is too hot Check if the customer s head position is set too far from the heater If it is reset it at the correct position See page 11 If the position is correctly set check that the sensor sheet i...

Page 12: ...mediately stop using the product The far infrared rays from the Roller Ball will not affect the human body at all but the customer may feel sick due to the heat if the customer is in poor health condi...

Page 13: ...position the infrared thermal sensor directly measures the customer s head temperature to control it to the preset temperature However if the head has moved significantly during operation the infrared...

Page 14: ...s And the selected mode and the decimal point of time indication blink at intervals of one second and the remaining time is displayed Press the mode selection button When the button is pressed the lam...

Page 15: ...e sure to turn off the power switch when finished When the preset time has elapsed and the time indication is zero 0 the cooling operation will be started For the setting of ring rotation and stop it...

Page 16: ...SIDE or NAPE The heater of the rotating ring can be set to OFF only when it passes the designated part Only for the Manual Mode Operation During operation When the operation is interrupted When the o...

Page 17: ...ink Blink Blink Blink Blink Blink Blink 1 sec OFF Customized Settings It is possible to adjust the initial settings in each mode as required customized settings The initial settings are displayed when...

Page 18: ...stop when the fire burns out causing no damage to the product If the fouling is substantial or the smoke does not stop turn off the power switch and contact the nearest dealer or Takara Belmont direc...

Page 19: ...on turn off the power and contact the nearest dealer or Takara Belmont directly Check if the ring does not interrupt wall or other equipment Move the product to the position where the ring does not co...

Page 20: ...rgents and wax containing abrasive compound sponge scrubber etc Splashing of water on the control panel or metal parts may result in product failure or rusting Immediately dry the product with a soft...

Page 21: ...acket is swinging from at its base on the wall disconnect the power plug and immediately contact the nearest dealer or Takara Belmont directly There is a possibility of electrical shock or burn injuri...

Page 22: ...94 5 485 406 AC110V 50 60Hz AC220V Specifications are subject to change without notice Model No AK S23A AK S23AF Electrical requirements Weight 8 0kg Safety device Rotation clutch mechanism Power supp...

Page 23: ...1546 Operation Distance 1 5 6 6 45 The above shows reference values when the lower end of the wall mount plate is installed at a height of 1900 mm from the floor surface 5 0 1219 2231 8 0 0 3 0 1012 2...

Page 24: ...1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan Printed in Japan TAKARA BELMONT CORPORATION TEL 06 6213 5945 FAX 06 6212 3680...