O p e r a t i n g   Pr o c e d u r e s

14

Settings excluding mode selection can be changed during
the operation.

[Changing the settings during operation]

If  the  customer s  head  move s  from  the  correc t 
position  and  the  infrared  heater  is  not  radiating  to 
the  head  correctly,  the  infrared  thermal  sensor  will 
detect  it  and  a  warning  alarm  will  sound  every  30 
seconds.  If  this  happens,  ask  the  customer  to  return 
to  the  origina l  position .  If  this  conditio n  is  not 
corrected, it may cause an unsatisfactory results.

[Warning of Head Position Misalignment]

(For COLOR, PERM, and TREATMENT modes)

Press the Start/Stop button during operation to stop 
ring  rotation  and  heater  control,  and  the  Start/Stop 
lamp blinks.

During  interrupte d  operation ,  the  setting  can  be 
changed.  When  the  mode  is  changed,  the  operation 
mode  shifts  to  the  changed  mode,  and  the  operation 
is in the standby state.

Press the Start/Stop button within five minutes after 
interrupting  the  operation  to  resume  operation.  If 
the  Start/Sto p  button  is  not  pressed  within  five 
minutes,  the  mode  will  reset  to  the  mode  before 
starting operation.

[Interrupting the operation]

6

Cooling

8

Be sure to turn off the power switch 
when finished.

When  the  preset  time  has  elapsed  and  the  time 
indication  is  zero  (0),  the  cooling  operation  will  be 
started.

※For  the  setting  of  ring  rotation  and  stop,  it  can  be 
changed only for manual mode.

7

Time‑up

When  the  preset  time  has  elapsed ,  the  time 
indication shows 0, the electronic alarm indicating a 
time‑up will be heard. The ring will stop at the home 
position.

Specification w/o Fan

Cooling process continues for one minute.
* During the cooling operation, the ring will 
   rotate when the heater is OFF.
* For the ring‑fixed operation in manual mode,
   cooling operation is not executed.

Specification w/ Fan

Cooling process continues for two minutes. 
During the cooling operation, cold air will be 
blown from the fan.
* In manual mode, the fan will not operate 
   during the cooling process, and as is the 
   case with the specification w/o fan, the 
   cooling time is one minute.

After the time‑up, the retention time will blink on 
the display panel.

[Counting the retention time]

The  retention  time  after  time‑up  is  displayed  up 
to  60  minutes.  When  the  Start/Stop  button  is 
pressed during this time, the previous setting will 
be  displayed .  (This  functio n  is  useful  when 
checking the operating time and the finished result 
in  comparison.)  When  the  mode  is  changed,  the 
memory is erased.

[Memory Function]

Summary of Contents for Roller Ball AK-S23A

Page 1: ...dure Information Dimensions and Specifications Lamp Indication during Operation and Inputs from Button Customized Settings Safety Precautions To be strictly observed Name of Each Part Thank you for pu...

Page 2: ...tes enforcement or instructions for general user behavior Indicates the prohibition of disassembly repair or modification Indicates the need for paying attention to high temperatures Indicates the pro...

Page 3: ...r to contact the heater guard while the customer dozes during operation or after using the Roller Ball Neglecting this warning may result in a burn injuries Do not suspend anything from the product or...

Page 4: ...g operation or right after the use Do not touch the ring including the ring heater heater guard reflector etc during operation or right after the use of the Roller Ball Neglecting this caution may res...

Page 5: ...red rays the infrared thermal sensor can correctly measure the hair temperature thereby enabling correct temperature control Do not allow the chemicals to adhere to the heater Use the product while pa...

Page 6: ...5 Guide Bar Nape Guard Heater Guard Power Switch Fuse Control Panel Reflector Ring Heater Infrared Thermal Sensor Top Cover Sensor Sheet Ring Cover Upper Shaft Grip Specification with Fan Shaft Cover...

Page 7: ...6 15P Operating Manual 1 copy MAY CAUSE BURNS DO NOT TOUCH THE HEATER GUARD MAY CAUSE THE DAMAGE ON THE HEATER DO NOT GIVE AN EXCESSIVE SHOCK TO THE RING Accessories Location of Warning Label...

Page 8: ...setting Each press of the UP or the DOWN button changes the temperature level by one step The level can be set in seven steps Each press of the UP or the DOWN button changes the time in units of a min...

Page 9: ...ng Rotation Button and Lamp Mute Button and Lamp Fan Button and Lamp Only for the specification with fan Lamp Lamp Lamp Use the button to stop or rotate the ring at a desired position Only for the man...

Page 10: ...emperature Control System Temp Level Time Heating Position Temperature control by infrared thermal sensor Temperature level and temperature settings Heating position Rotation Hot double process perms...

Page 11: ...ead is too hot Check if the customer s head position is set too far from the heater If it is reset it at the correct position See page 11 If the position is correctly set check that the sensor sheet i...

Page 12: ...mediately stop using the product The far infrared rays from the Roller Ball will not affect the human body at all but the customer may feel sick due to the heat if the customer is in poor health condi...

Page 13: ...position the infrared thermal sensor directly measures the customer s head temperature to control it to the preset temperature However if the head has moved significantly during operation the infrared...

Page 14: ...s And the selected mode and the decimal point of time indication blink at intervals of one second and the remaining time is displayed Press the mode selection button When the button is pressed the lam...

Page 15: ...e sure to turn off the power switch when finished When the preset time has elapsed and the time indication is zero 0 the cooling operation will be started For the setting of ring rotation and stop it...

Page 16: ...SIDE or NAPE The heater of the rotating ring can be set to OFF only when it passes the designated part Only for the Manual Mode Operation During operation When the operation is interrupted When the o...

Page 17: ...ink Blink Blink Blink Blink Blink Blink 1 sec OFF Customized Settings It is possible to adjust the initial settings in each mode as required customized settings The initial settings are displayed when...

Page 18: ...stop when the fire burns out causing no damage to the product If the fouling is substantial or the smoke does not stop turn off the power switch and contact the nearest dealer or Takara Belmont direc...

Page 19: ...on turn off the power and contact the nearest dealer or Takara Belmont directly Check if the ring does not interrupt wall or other equipment Move the product to the position where the ring does not co...

Page 20: ...rgents and wax containing abrasive compound sponge scrubber etc Splashing of water on the control panel or metal parts may result in product failure or rusting Immediately dry the product with a soft...

Page 21: ...acket is swinging from at its base on the wall disconnect the power plug and immediately contact the nearest dealer or Takara Belmont directly There is a possibility of electrical shock or burn injuri...

Page 22: ...94 5 485 406 AC110V 50 60Hz AC220V Specifications are subject to change without notice Model No AK S23A AK S23AF Electrical requirements Weight 8 0kg Safety device Rotation clutch mechanism Power supp...

Page 23: ...1546 Operation Distance 1 5 6 6 45 The above shows reference values when the lower end of the wall mount plate is installed at a height of 1900 mm from the floor surface 5 0 1219 2231 8 0 0 3 0 1012 2...

Page 24: ...1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan Printed in Japan TAKARA BELMONT CORPORATION TEL 06 6213 5945 FAX 06 6212 3680...

Reviews: