O p e r a t i n g Pr o c e d u r e s
14
Settings excluding mode selection can be changed during
the operation.
[Changing the settings during operation]
If the customer s head move s from the correc t
position and the infrared heater is not radiating to
the head correctly, the infrared thermal sensor will
detect it and a warning alarm will sound every 30
seconds. If this happens, ask the customer to return
to the origina l position . If this conditio n is not
corrected, it may cause an unsatisfactory results.
[Warning of Head Position Misalignment]
(For COLOR, PERM, and TREATMENT modes)
Press the Start/Stop button during operation to stop
ring rotation and heater control, and the Start/Stop
lamp blinks.
During interrupte d operation , the setting can be
changed. When the mode is changed, the operation
mode shifts to the changed mode, and the operation
is in the standby state.
Press the Start/Stop button within five minutes after
interrupting the operation to resume operation. If
the Start/Sto p button is not pressed within five
minutes, the mode will reset to the mode before
starting operation.
[Interrupting the operation]
6
Cooling
8
Be sure to turn off the power switch
when finished.
When the preset time has elapsed and the time
indication is zero (0), the cooling operation will be
started.
※For the setting of ring rotation and stop, it can be
changed only for manual mode.
7
Time‑up
When the preset time has elapsed , the time
indication shows 0, the electronic alarm indicating a
time‑up will be heard. The ring will stop at the home
position.
Specification w/o Fan
Cooling process continues for one minute.
* During the cooling operation, the ring will
rotate when the heater is OFF.
* For the ring‑fixed operation in manual mode,
cooling operation is not executed.
Specification w/ Fan
Cooling process continues for two minutes.
During the cooling operation, cold air will be
blown from the fan.
* In manual mode, the fan will not operate
during the cooling process, and as is the
case with the specification w/o fan, the
cooling time is one minute.
After the time‑up, the retention time will blink on
the display panel.
[Counting the retention time]
The retention time after time‑up is displayed up
to 60 minutes. When the Start/Stop button is
pressed during this time, the previous setting will
be displayed . (This functio n is useful when
checking the operating time and the finished result
in comparison.) When the mode is changed, the
memory is erased.
[Memory Function]