51
Page
NOTICE
•
The controllers have an energy saving mode. Five minutes after the water
heater stops operating, the backlight of the controllers turns off.
•
The backlight of the controllers will turn back on once the water heater begins
firing again.
Normal Operation
Owner's Guide
Operation
Controllers
Built-in controller
Remote controller
1.
Turn on the 120 VAC power supply to the unit.
2.
Press the
"ON/OFF"
button on the controller in order to
turn the controller on.
3.
When ON, the STAND BY LED is lit.
4.
It shows
the set temperature of output water on its
display as shown in the picture on the right. (EX.: 120 °F)
5.
Press the
"HOT"
button or the
"COLD"
button to set the
temperature setting of the unit.
Increasing temperature from 120 °F (50 °C) to 125 °F (52 °C) :
1. The water heater must be in Stand By to increase the
temperature.
2. Press the "HOT" button to set 120 °F (50 °C).
3. Press and hold the "INFO" button and the "HOT"
button for at least 3 seconds. The remote will emit a
beep and change to 125 °F (52 °C).
4. Press the "HOT" button to set up to 140 °F (60 °C).
(EX.: 120 °F)
OUTLET WATER TEMPERATURE SETTING
-Set temperature-
TEMPERATURE TABLE OF CONTROLLER
°F
100 105 110 115 120* 125 130 135 140
°C
38
40
43
45 50* 52
55
57
60
*Factory setting (Default):
120 °F (50 °C)