66
Page
Troubleshooting
Owner's Guide
Error code
ERROR CODES
-General-
•
The units have self-diagnostic functions for safety and convenience when troubleshooting.
•
If there is a problem with the installation or the unit, the error code will be displayed on the built-in
controller or remote controller.
•
Consult the table on the following pages for the description of each error code.
-Single unit Installations-
Example: If your unit has the “321” error code (which signifies an inlet thermistor failure)
•
Indicator on the built-in controller
and/or remote controller:
“321” will be displayed
on the screen in its entirety.
•
Green LED on the computer board:
The green LED on the computer board will indicate this code with
two flashes every 1/2 second. The pattern will repeat with a three second delay between patterns.
Error code
Green LED
on
on
on
on
on
on
off
off
off
off
off
321
Error Indication
540P computer board
Green LED flashes to indicate error code.
Error code indicator on
the built-in controller
Error code indicator on
the remote controller
Error Code
on the temperature
controller
Green LED
The number
of
flashes
Flash
pa
tt
ern
031 701 711
One
311 321 331 341
351 391 441
Two
111 121
Three
611 631 651 661
Four
101 941 991
Five
510 551 721
Six
on
on
off
off
0.5 sec. on, O.5 sec. off
3 sec. off