84
Specifications
T801-4 Installation and Operation Manual
© Tait Electronics Limited September 2007
Operational
Supply Voltage
Operating Voltage
Standard Test Voltage
Polarity
Polarity Protection
10.5VDC to 28VDC
13.8VDC
negative earth only
diode
Supply Current
a
T801-41-8000 with Dalman external
GPS receiver
T801-41-8100 with Trimble internal
GPS receiver and Bullet III antenna
T801-42-8000 with Dalman external
GPS receiver
T801-42-8100 with Trimble internal
GPS receiver and Bullet III antenna
1.4A
0.7A
1.9A
1.3A
a. Measured at 21°C ambient temperature with all 1PPS TTL outputs loaded (50
Ω
).
Operating Temperature Range
–30°C to +60°C (–22°F to +140°F) ambient
temperature
b
b. Ambient temperature is defined as the temperature of the air circulating around the T801-4 inside the rack or cabinet
during normal operation. It does not refer to the temperature in the equipment room.
Physical
Cooling
convection
Connectors
Programming Port
Frequency Reference Outputs
1PPS TTL Outputs
RF Input from GPS Antenna
Recommended SMA Torque
I/O Port
Interface to External GPS Receiver
Interface to QS
2
RSU
DC Input
Chassis Ground
9-way D-range female (RS-232)
BNC female
BNC female
SMA female
0.9N·m (8lbf·in)
9-way D-range male
15-way D-range female (RS-485)
RJ45 (RS-485)
Phoenix Contact FKC series
5mm threaded stud
Dimensions
Height
Width
Chassis
Front Panel
Length
43.5mm (1.7in) (1U nominal)
440mm (17.3in)
482.6mm (19in)
303mm (11.9in)