XT-1/XT Mini Manual
13-111 05, 2015-08-14
Page 26 of 32
5.1.1.5
Paxton Net2 Plus
Configure the Paxton system to use reader type "Clock & Data".
GND
0V
IN1+
12V
CL/LOAD
N/C
IN1-
Green LED
D0/CLK
Clock/D1
IN2+
12V
D1/DATA
Data/D0
IN2-
Red LED
S101 - Magstripe format: M8N/H10320
S301 - Vigilant pull-ups disabled
Tested version: Net2 Lite version 4.28.8417
5.1.1.6
RCO R-CARD M5 (with DB-50W)
The RCO system automatically detects the Wiegand format.
GND
DC-
IN1+
N/C
CL/LOAD
N/C
IN1-
N/C
D0/CLK
DATA0
IN2+
N/C
D1/DATA
DATA1
IN2-
N/C
S101
S301 - Vigilant pull-ups enabled
Strap at P14*:
Wiegand format:
W34N
No strap at P14:
Wiegand format:
W26S/H10302
* To get all digits from the SecureMarkID tag, it is necessary to solder a strap at P14 on the RCO DB-50W
board. Without this strap it is only possible to get the last four digits from the tag.
5.1.1.7
Vanderbilt Aliro
On the circuit board in the access point, set the EOL jumper for the reader to OFF.
In the Aliro software, set reader type to "Wiegand" and card format to "H10302_37".
Configure Output_1 to "C&D/Wiegand green" and Output_2 to "C&D/Wiegand red".
GND
[READER n] -
IN1+
[READER n] +
CL/LOAD
N/C
IN1-
[OUT 1/2 ] 1
D0/CLK
[READER n] A
IN2+
[READER n] +
D1/DATA
[READER n] B
IN2-
[OUT 1/2 ] 2
S101 - Wiegand format: W37N/H10302
S301 - Vigilant pull-ups enabled
Tested version: Software version 1.0.0.5371, Access point firmware version 1.0.0.2022
1
8
ON
S101
1
8
ON
S301
1
8
ON
S301
1
8
ON
S101
1
8
ON
S101
1
8
ON
S101
1
8
ON
S301
Summary of Contents for XT Mini
Page 1: ...XT 1 XT Mini Manual ...