Wiegand/Magstripe
The reader has a software configurable Wiegand/Magstripe interface.
Connections
(Wiegand)
WIEG:D0
Wiegand 0
WIEG:D1
Wiegand 1
WIEG:CL
Card load
WIEG:GND
Signal ground #1
Connections
(Magstripe)
MAG:CLK
Magstripe clock
MAG:DATA
Magstripe data
MAG:LOAD Card load
MAG:GND
Signal ground #1
Max cable length
100 m (depending on properties of receiving system)
Wire size
0.5 mm
2
(AWG 20), 1.5 mm
2
(AWG 16) above 10 m of length.
Voltage
Typ 5 V / Max 30 V
Sink current
Max 500 mA
Isolation
Min 1500 VDC
Table 4 Wiegand connection overview
All Wiegand/Magstripe settings are available under Settings…/Interfaces…/Wieg/Mag in the web interface.
It is possible to select a predefined format or define a custom format.
The most common predefined formats can be selected by setting DIP switches S101:6-8 as shown in the
table below. When any of these switches are in the ON position, the reader is also configured to report tags
once and only accept SecureMarkID tags.
The following formats can be selected by DIP switches:
D = Data from tag (bit for Wiegand/digit for Magstripe)
S = Value of Site code
E = Even parity bit, O = Odd parity bit, X = Bit included in parity calculation
B = Magstripe start character, F = Magstripe stop character, L = Magstripe LRC
Output Format
Description
W26S/H10301
26-bit Wiegand (8-bit site code, 16-bit data):
ESSSSSSSSDDDDDDDDDDDDDDDDO
XXXXXXXXXXXXX-------------
-------------XXXXXXXXXXXXX
W26N/H10301
26-bit Wiegand (24-bit data, no site code):
EDDDDDDDDDDDDDDDDDDDDDDDDO
XXXXXXXXXXXXX-------------
-------------XXXXXXXXXXXXX
W34N
34-bit Wiegand (32-bit data, no site code):
EDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDO
XXXXXXXXXXXXXXXXX-----------------
-----------------XXXXXXXXXXXXXXXXX
1
8
ON
S101
1
8
ON
S101
1
8
ON
S101