XT-1/XT Mini Manual
13-111 05, 2015-08-14
Page 11 of 32
3
Interfaces
Overview
Figure 10 shows the locations of the different interfaces in XT-1 and XT Mini. The name of each interface is
listed in Table 2. The following sections refer to the interfaces as named in the table.
Figure 10 XT-1 (left) and XT Mini (right) interfaces
Position Interface(s)
1
POWER, RS232, RS485, INPUTS, WIEG/MAG, RELAY, TMP (XT Mini only)
2
ETHERNET
3
USB
4
DIP S301
5
DIP S101
6
MICROSD
Table 2 Interface names
Power Supply
The reader shall be powered by an isolated power supply suitable for outdoor use. The required voltage is
12 VDC to 24 VDC. It is recommended to use a power supply of 24 VDC, 0.5 A minimum.
The power input has built-in reverse polarity protection.
Connections
POWER:DC+ High supply potential
POWER:DC-
Low supply potential (ground)
Supply voltage
12 VDC to 24 VDC
(Absolute minimum rating 10 VDC, absolute maximum rating 30 VDC)
Max cable length
100 m
Wire size
Recommended 1.5 mm
2
(AWG 16)
Table 3 Power connection overview
1
3
2
6
4
5
1
6
5
4
1
2
3
Summary of Contents for XT Mini
Page 1: ...XT 1 XT Mini Manual ...