Y-5
Y-5
Adjusting Procedure (Electric)
32
WY04-2172E
6. Control lever stand position detection
switch (left) (CN529)
Set the clearance B to minimum, and adjust switch
position so that the dimension A becomes 1.5
+0.5
0
mm (0.06
+0.02
0
in).
(*1):
•
Apply a thread locking agent (ThreeBond 1401
or the equivalent) to the threaded section of
the switch.
•
Switch fixing nut tightening torque
: 19 to 20 N-m (193 to 204 kgf-cm)
(14 to 14.8 ft-lbf)
7. Straight ahead detection switch
(CN408)
Set the rear wheels in a straight-forward position,
and adjust the switch position so that the dimension
A becomes 3
0
–0.5
mm (0.12
0
–0.02
in).
(*1):
•
Apply a thread locking agent (ThreeBond 1401
or the equivalent) to the threaded section of
the switch.
•
Switch fixing nut tightening torque
: 19 to 20 N-m (193 to 204 kgf-cm)
(14 to 14.8 ft-lbf)
[NOTICE]
Make sure that the green LED lights up when the
switch is activated.
△
5
343-232-51000
△
0
349-609-80000
△
5
343-233-01000