Operation
Air releasing
Air-release method A
Before proceeding with the air releasing, check that the
end of the relief/air-release hose has been led back to
the tank or other container.
(1) Turn off the pump’s power, and release the pressure
inside the discharge side pipe.
(2) Set the stroke length adjustment dial to 100%.
Stroke length
adjustment dial
(3) Turn the air-release knob clockwise (toward the
right) by about 90 degrees.
The clearance between the knob and clamp nut can
be seen.
Air-release knob
Gap
Retaining nut
(4) Turn on the pump’s power.
(5) Set the discharge capacity to the maximum. (This
can also be done by pressing the [
] and [
] keys
simultaneously during operation.)
(6) Press the [STOP/START] key to operate the pump.
(7) After a few moments, the chemical liquid drains
off and the air is vented from the chemical liquid
escape port.
(8) When all the air has been vented, turn the air-
release knob clockwise (toward the right) until a
clicking sound is heard.
(9) Press the [STOP/START] key to stop the pump.
(10) Return the stroke-length adjustment dial to the
marking on the scale that it was previously set to.
IMPORTANT
• Under no circumstances must the air-release
knob be turned counterclockwise.
NOTE
• If it is difficult to release the air, keep turning
the air-release knob clockwise until a
clicking sound is heard repeatedly.