12
Installation
Connecting
I. Pump below-tank mounting position (w/ relief valve)
II. Pump below-tank mounting position (w/o relief valve)
III. Pump below-tank mounting position (w/ relief valve)
IV. Pump below-tank mounting position (w/o relief valve)
V. Pump above-tank mounting (w/ relief valve)
VI. Pump above-tank mounting (w/o relief valve)
Applicable models:PW
/CLPW
-30R/60R/100R
Applicable models:PW
/CLPW
-30/60/100/200
Applicable models:DCLPW
-30R/60R/100R
Applicable models:DCLPW
-30/60/100
Applicable models:PW
/CLPW
-30R/60R/100R
Applicable models:PW
/CLPW
-30/60/100/200
Main pipe
Anti-siphonal check valve
Valve
Tank
Relief/air-release hose
Main pipe
Anti-siphonal check valve
Valve
Tank
Relief/air-release hose
Air-release
hose
Air-release
hose
Degassing joint
Main pipe
Anti-siphonal check valve
Valve
Tank
Relief/air-release hose
Main pipe
Anti-siphonal check valve
Relief valve
Degassing joint
Valve
Tank
Main pipe
Anti-siphonal check valve
Valve
Tank
Degassing joint
Anti-siphonal check valve
Relief valve
Degassing joint
Main pipe
Valve
Tank
Relief valve
Degassing joint
✽
Pump above-tank mounting cannot be used for the DCLPW
and high-viscosity type.
✽
If at all possible, use pump below-tank mounting position for the CLPW
.
✽
When using the pump in an above-tank mounting position, moisten the valve seat area with some water or
chemical liquid before operating the pump.
✽
This pump has a maximum suction height of -1.5 m for water in the condition with the valve seat area mois-
tened. The suction capability may decrease when the valve seat area is dry. (Except the DCLPW
, CLPW
and high-viscosity types)
08-32̲EM-127̲PW(E).indd 12