![Tacmina CLPW Series Operation Manual Download Page 25](http://html.mh-extra.com/html/tacmina/clpw-series/clpw-series_operation-manual_812762025.webp)
24
Operation
Air releasing
Air-release method B
(1) Insert the accessory air-release hose (4 mm dia. ×
6 mm dia.) into the air-release port. (Ensure that the
hose is inserted all the way to its base.)
Check that the other end of the hose is brought back
to the tank, etc.
Air-
release
port
Air-release
nozzle
Air-release hose
(2) Turn off the pump’s power, and release the pressure
inside the discharge-side pipe.
(3) Set the stroke-length adjustment dial to the 100%
marking on the scale.
Stroke length
adjustment dial
(4) Turn on the pump’s power.
(5) Press the [STOP/START] key to start operating the
pump.
(6) Press the [
] and [
] keys simultaneously during
operation. (This can also be done by setting the dis-
charge capacity to the maximum.)
(7) While operating the pump, turn the air-release knob
counterclockwise (toward the left) for between 1 and
1.5 turns.
The air remaining inside the suction side hose and
pump head is discharged from the air-release valve, and
the chemical liquid fills the inside of the pump head.
Air-release
knob
(8) Discharge from the air-release nozzle any remaining
air in the suction-side hose and pump head, check
that the pump head is full of liquid, and then release
the [
] and [
] keys.
While this is happening, chemical liquid will emerge
from the air-release port so tighten the air-release knob.
✽
If the air is not readily released, repeatedly open
and close the air-release knob.
(9) Press the [STOP/START] key to shut down the
pump.
(10) Return the stroke-length adjustment dial to the
marking on the scale that it was previously set to.
08-32̲EM-127̲PW(E).indd 24