PAGE
Section 4 • Installation Guide
Most conventional “lipped” plates (Type 1)
sit comfortably over the grey mounting
plate, secured simply by fitting the
mounting screws in the conventional way.
Type 2 plates require the mounting frame
to be milled to fit. Suitable guideline milling
drawings are available on request.
Type 3 plates are completely flush and
therefore require the grey mounting frame
to be inset into the back box. Suitable
frames are available to special order.
Connecting Modules. Data cable
terminations and connections are made
in the same way as previously detailed in
Section 4.14. Note that each DMS has two
data terminals (labelled IN and OUT)
located horizontally at the rear of the
module and the KMS has two data
terminals (labelled IN and OUT) located
vertically at the rear of the module.
Remember that a DMS module connected
to the zone A data cable terminal
MUST
be used for initial set-up, particularly in
systems where non-RC5 source
components are included. Details will be
found in Section 5.23.
4.23 Fitting DMS & KMS Modules
into Back Box & Wall Plates
1) Clip module into grey mounting frame, as
shown.
2) Make all necessary wire connections to
module.
3) Screw in to wall box.
4) Clip on System 45* facia plate.
*System 45 and Sistema 45 are trade marks of
Hamilton Ltd. England and Ave Spa Italy
respectively. Alternative versions of
mounting plates and facias are available to
fit a wide variety of mainland European
back-boxes including the round type -
please ask your distributor for details.
A very wide variety of System 45 facias are
available in numerous colours and finishes,
but should you wish to use non-System 45
facias, you will first need determine the
category of the type of plates you wish to
use.
TYPE 1
TYPE 2
TYPE 3
CROSS SECTIONS
Grey mounting
frame
Module
System 45
range facia
Rear View of DMS
Rear View of KMS
17