PAGE
The DIP switches must be set on every
DMS module for the system to function
correctly. The following table shows the
available setting options for each switch:
Switch 1
OFF
OFF
ON
ON
Switch 3
OFF
ON
Switch 4
OFF
OFF
ON
ON
Switch 6
OFF
ON
Switch 7
OFF
ON
Switch 8
OFF
ON
Switch 2
OFF
ON
OFF
ON
Source 3
Tape
Sat
Switch 5
OFF
ON
OFF
ON
DMS is
Master
Slave
DMS reset
Default
Reset
Battery
Shipping
Position
Once
Installed
Address
Zone A
Zone B
Zone C
Zone D
Source 4
Dvd
Tun 2
Vcr
Cd 2
Zone Configuration. Select the required
zone for the DMS module by setting DIP
switches 1 and 2 as appropriate.
Component Source Configuration.
Sources 1 and 2 are set as standard to
tuner and CD respectively. Set DIP switch
3 as appropriate to configure source 3 as
a tape deck or satellite/cable. Set DIP
switches 4 and 5 as appropriate to
configure source 4 as a Dvd, Vcr, Cd 2 or
Tun 2.
Master / Slave Configuration. In all zones
where DMS modules are fitted, ONE DMS
module must be set as a MASTER (DIP
switch 6 = OFF) and all others set as
slaves (DIP switch 6 = ON). The MASTER
should be the first module in the serial
connection sequence, i.e. the one nearest
to the controller.
Internal Battery. Each DMS module
contains a rechargeable battery which
maintains the clock and other
configuration information when power to
the Controller is switched off. The battery
must be enabled during DMS installation.
Section 4 • Installation Guide
When fully charged, the battery will
maintain the stored information for
several weeks without recharging.
To enable the battery, set DIP switch 8 to
ON.
NOTE 1: After the display configuration
has been changed, DIP switch 7 must be
set to ON and then returned to OFF to
reset the system.
NOTE 2: After installation, leave the
Controller on continuously for a few days
to ensure that the internal battery is fully
charged.
4.22 The KMS Keypad
a) There are no restrictions on where the
KMS can be located. Common sense and
user convenience should be the
determining factors. Avoid using the
keypad in damp environments e.g.
bathroom. If the keypad needs to be
mounted externally a waterproof
enclosure should be used. These are
available from QED.
b) KMSs do not need to be set for particular
zones as they do not display zone or
system status information.
16