70
Note
If an input is made outside of the permissible range, a buzzer will
sound and the hexadecimal display will not be displayed.
WRITE
00203 ADB DATA C
000
17. Input the final operand and then press the WRITE Key.
DM
00203 ADB DATA C
DM 0000
WRITE
00204READ
NOP(000)
1-3-10 Checking the Program
This operation checks for programming errors and displays the program ad-
dress and error when errors are found. It is possible in PROGRAM mode
only.
RUN
MONITOR
PROGRAM
No
No
OK
1, 2, 3...
1. Press the CLR Key to bring up the initial display.
2. Press the SRCH Key. An input prompt will appear requesting the desired
check level.
SRCH
00000PROG CHK
CHK LBL (0-2)?
3. Input the desired check level (0, 1, or 2). The program check will begin when
the check level is input, and the first error found will be displayed.
A
0
00178CIRCUIT ERR
OUT
00200
Note
Refer to
NO TAG Programming Errors
for details on check levels.
4. Press the SRCH Key to continue the search. The next error will be dis-
played. Continue pressing the SRCH Key to continue the search.
The search will continue until an END instruction or the end of Program
Memory is reached. A display like this will appear if the end of Program
Memory is reached:
SRCH
00300NO END INST
END
A display like this will appear if an END instruction is reached:
SRCH
00310PROG CHK
END (001)00.3KW
If errors are displayed, edit the program to correct the errors and check the pro-
gram again. Continue checking the program until all errors have been corrected.
1-3-11 Bit, Digit, Word Monitor
This operation is used to monitor the status of up to 16 bits and words, al-
though only 3 can be shown on the display at any one time. Operation is pos-
sible in any mode.
RUN
MONITOR
PROGRAM
OK
OK
OK
Program Read then Monitor
When a program address is being displayed, the status of the bit or word in that
address can be monitored by pressing the MONTR Key.
1, 2, 3...
1. Press the CLR Key to bring up the initial display.
Programming Console Operations
Section 1-3
Summary of Contents for CPM1A-20CAR-A
Page 3: ...ii...
Page 5: ...iv...
Page 9: ...iv...
Page 29: ...14 System Configuration Section 1 2...
Page 43: ...29 Unit Components Section 2 2...
Page 65: ...51 Wiring and Connections Section 3 4...
Page 123: ...Appendix B Dimensions 2 CPM1 CIF01 90 81 21 30 205 50 56 CPM1 CIF11 90 81 21 30 205 50 61...
Page 124: ...Appendix B Dimensions 3 Dimensions with Peripheral Devices Attached Approx 90 Approx 125...
Page 125: ...Appendix B Dimensions 4...