OPERATION
B.
J20 MULTI-ENCODER OUTPUT SELECT
This jumper configures the Multi-Encoder to output translated time, generated time, or in
the automatic mode (with no jumper installed), to generate the time displayed on the front
panel LED Display.
J20
3
2
1
GENERATOR
SELECTION
J20
3
2
1
AUTOMATIC
J20
3
2
1
TRANSLATOR
SELECTION
Note:
The factory default setting for this jumper is Automatic. Power must be cycled for
a jumper change to be effective.
C.
J22 REAR PANEL BNC J5 CONFIGURATION
Internal jumper J22 provides selection of J5 (rear panel BNC) as an external oscillator
input or a 10MHz sine wave output.
J22
1
2
3
10MHz
OUTPUT ENABLED
J22
1
2
3
EXT. OSC.
INPUT ENABLED
Note:
The factory default setting for this jumper is Ext. Osc. Input Enabled.
3.3
INDICATORS
The following paragraphs give an explanation of the indicators used in this unit:
3.3.1 LCD
DISPLAY
The LCD Display is used to display menus for operator prompting, instrument status, and the
function of the select switches. The LCD Display is located on the right half of the front panel
just above the SELECT switches. See Figure 3.1.
3.3.2 LED
DISPLAY
The LED Display is normally used to display Time-of-Year. The time displayed is automatically
selected from the Generator or the Translator according to the menu chosen. The LED Display is
located on the left half of the TM7000 front panel. See Figure 3.1.