APPENDIX A
1.3.2 FRZ
Freeze. A ground true signal which prevents data update while active (low). 100 nanoseconds after
freeze is initiated, the data is static. 11 microseconds after freeze is removed, the data will again
start updating.
1.3.3 ENOUT
Enable Output. A ground true input which enables the output drivers. If driven by an open
collector output from the destination equipment, such equipment will not load this option when
powered down. This input may be grounded at J1.
1.3.4 SAMPLE
A pulse which indicates validity of time. May be used to clock external equipment. The pulse may
be inverted by installing a jumper between E4 and E5 (E5-E6 is provided for storage). The pulse
rate is selectable from 1pps-100Kpps. See Table Three.
1.3.5 JUMPERS E1, E2, E3
Placing a jumper from E1 to E2 forces output of generated time. Placing a jumper from E2 to E3
forces output of translated time. Without a jumper, time follows the LED display.
Output connector is 62 pin micro-miniature “D” type. See Table Two for signal connections.
Table Three
Sample Time Rate Selection
Desired Rate
Required Jumper
1 pps
E7-E8
10 pps
E9-E10
100 pps
E11-E12
1K pps
E13-E14
10K pps
E15-E16
100K pps
E17-E18
A-12
TM7000 TymMachine TCG/T (Rev D)
Symmetricom, Inc.