CHAPTER THREE
The Multi-Code Serial Encoder may get time information from either the Generator or Translator
according to which mode has been selected, or may be forced by a jumper to output either
translator time or generator time, regardless of the mode of the TM7000. See Paragraph 3.2.5 B.
This assembly is shipped with a jumper installed from J20 1-2 to force Generator time.
3.7.17 RS-232 I/O OPERATION/CONFIGURATION
Back on the Generator Set-Up Menu, Figure 3.7.17.2, selecting the “RS-232” mode of operation
will lead to the LCD Display showing the BAUD Rate Selection, Figure 3.7.17.1.
Note:
The factory default selection of the RS-232 I/O is 9600 BAUD, 8 bit word length,
no parity, and 1 stop bit.
Select BAUD Rate
Figure 3.7.17.1
Select
Baud
Rate
SLOWER
1200
FASTER
Pressing a switch under either “SLOWER” or “FASTER” will increase or decrease the BAUD
rate from that currently displayed. Available baud rates are 50, 75, 110, 134.5, 150, 300, 600,
1200, 1800, 2400, 3600, 4800, 7200, 9600, 19200, and 38400. The receiver and transmitter are
always set to the same baud rate.
Pressing the PREV switch will return the LCD Display to the Generator Set-Up Menu as shown
below:
Generator Setup Menu
Figure 3.7.17.2
Set-up generator.
INPUTS OUTPUTS RS232 488 BUS GPIO
Pressing the NEXT switch will allow the user to select parity and stop bits.
Parity can be turned off or set to either even or odd. Either one or two stop bits can be selected.
Parity disabled and one stop bit:
OFF
Figure 3.7.17.3
Parity Select
*
Stop Bits Select
OFF - odd - even
*
ONE - two
3-18