APPENDIX A
TM Option 17
Read DC Code
Assembly 19395
1.1 INTRODUCTION
This assembly is used to provide multi-speed DC code translating abilities in the TymMachine
7000. DC codes are input to this module, which provides a code output that must be externally
connected to the Translator Code input J8.
1.2 INSTALLATION
This assembly may be plugged into any available option position but should preferably be located
near J8.
•
Remove power from the TM7000.
•
Plug this assembly into any unused option slot, being careful that components are facing
upward.
•
Connect the DC code in to J3 of this assembly to the Code Input (J8) of the basic unit using the
coaxial cable supplied.
•
Apply power.
1.3 SPECIFICATIONS
DC Code
Input
Impedance:
>8K Ohms
Input Level:
+1V to +50Vpeak, positive, negative or bi-polar.
Polarity:
NORM/INV is selected by the Translating Menu.
Tracking Range: Selected Fre20%.
Speed
Range:
Code Selected:
Range (playback: real-time)
IRIG
G
1:1-4:1
IRIG A
1:1-32:1
IRIG B, E, H
1:1-256:1
A-34
TM7000 TymMachine TCG/T (Rev D)
Symmetricom, Inc.