OPTION DESCRIPTIONS
1.7.2
SCY (SINGLE CYCLE)
This is identical to STS except when the search cycle ends, a start command is automatically given.
To select this mode, push the SCY switch. SCY- - MULT (single cycle-multiple) is like a single
cycle except it performs a single cycle on all intervals from zero through the selected last interval.
1.7.3 SCY - - MULTI (SINGLE CYCLE-MULTIPLE)
This always begins with interval zero. To select this mode, push the SCY-MULT switch.
SCY- - MULT (single cycle-multiple) is like a single cycle except it performs a single cycle on all
intervals from zero through the selected last interval.
1.7.4 AUTOREC (AUTO RECORD)
Used in conjunction with a real time code input. It is used to initiate forward record at interval Start
Time and stop the recorder at interval Stop Time.
1.7.5 RCY
(RECYCLE)
This is like SCY except at the end of SCY another SCY is begun. To stop RCY, use the STOP
switch.
1.7.6 START
START is for use following STS.
1.7.7 STOP
STOP may be used at any time during any cycle to stop the transport. Stop should be used when
changing modes.
1.8
MAN-S (Manual Search Operation)
The following menu is associated with Manual Tape Search operation.
Pressing a switch under MAN-S while the Tape Search Set-Up Menu, Figure 7, is displayed on the
LCD causes the Manual Search Operating Menu, Figure 15, to be displayed.
Manual Search Operating Menu
? ST???:??:??:??.??? SP???:??:??:??.???
FWD FFWD REV FREV INC-INT REC STOP
Figure 15
Symmetricom, Inc.
TM7000 TymMachine TCG/T (Rev D)
A-9