098-00172-000 Revision A – December, 2009
TimeProvider 500 2.0 User’s Guide
149
TimeProvider 5000 and 500 Configuration Example
Configure GrandMaster IP Address
Use the IP address of the grandmaster
customized for your system network and
attach the grandmaster to one of the
TimeProvider 500’s Ethernet interfaces.
Perform the following steps:
1.
At the TP-500> prompt, type
set ptp
address gm1 192.168.1.15
2.
At the TP-500> prompt, type
set
interface attachments gm1 if0
.
View Management IP Address
Perform the following step:
1.
At the TP5000> prompt, type
show ip
status imc
<enter>
Confirm Grandmaster Address and PTP
Configuration
Perform the following step:
1.
At the TP-500> prompt, type
show ptp
<enter>
Enable Firewall for Telnet
Perform the following steps:
1.
At the TP5000> prompt, type
set
firewall imc telnet allow
<enter>
2.
At the TP5000> prompt, type
set ip imc
restart
<enter>
Connect Through an Ethernet LAN
Use an Ethernet cable to connect the IMC module
to the switch /router.
To telnet from your computer to the IP address of
the TP5000, type the following user name and
password:
User: admin
Password: symmadmin**
Table B-1. TimeProvider 5000 and 500 Configuration (Continued)
TimeProvider 5000
TimeProvider 500
Summary of Contents for TimeProvider 500
Page 10: ...Table of Contents 10 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Page 12: ...List of Figures 12 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Page 146: ...146 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 T1 Format ...
Page 174: ...Index W W 174 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...