AP-51xx Access Point Product Reference Guide
2-12
Ensure the cable length from the Ethernet source (host) to the Power Tap (or Power Injector)
and access point does not exceed 100 meters (333 ft). Neither the Power Tap or Power
Injector has an On/Off switch. Each receives power as soon as AC power is applied.
3.
For Power Tap installations, have a certified electrician open the Power Tap enclosure, feed
the power cable through the unit’s
LINE AC
connector, secure the power cable to the unit’s
three screw termination block and tighten the unit’s LINE AC clamp (by hand) to ensure the
power cable cannot be pulled from the unit and is protected from the elements.
4.
For Power Tap installations, attach a ground cable between the
EARTH GROUND
connector (on the back of the unit) to a suitable earth ground connection as defined by your
local electrical code.
5.
Verify all cable connections are complete before supplying power to the access point.
2.6.1.3 Power Injector LED Indicators
The Power Injector demonstrates the following LED behavior under normal and/or problematic
operating conditions:
For more information and device specifications for the Symbol Power Injector, refer to the
Power
Injector Quick Install Guide
(Part No. 72-70762-01) available from the Symbol Web site.
2.7 Mounting an AP-5131
The AP-5131 can rest on a flat surface, attach to a wall, mount under a suspended T-Bar or above a
ceiling (plenum or attic). Choose one of the following mounting options based on the physical
environment of the coverage area. Do not mount the AP-5131 in a location that has not been approved
in a site survey.
NOTE
The AP-5181 Power Tap (Part No. AP-PSBIAS-5181-01R) does not have
LED indicators.
LED AC
(Main)
Port
Green
(Steady)
Power Injector is receiving power from AC
outlet.
Indicates a device is connected to the
Power Injector’s outgoing Data & Power
cable.
Green
(Blinking)
Output voltage source is out of range.
The Power Injector is overloaded or has a
short circuit.
Summary of Contents for AP-51xx
Page 1: ...AP 51xx Access Point Product Reference Guide...
Page 2: ......
Page 3: ...AP 51xx Access Point Product Reference Guide 72E 92949 01 Revision A January 2007...
Page 4: ......
Page 6: ......
Page 16: ...AP 51xx Access Point Product Reference Guide xii...
Page 44: ...AP 51xx Access Point Product Reference Guide 1 26...
Page 76: ...AP 51xx Access Point Product Reference Guide 2 32...
Page 92: ...AP 51xx Access Point Product Reference Guide 3 16...
Page 214: ...AP 51xx Access Point Product Reference Guide 5 70...
Page 534: ...AP 51xx Access Point Product Reference Guide 8 208...
Page 590: ...AP 51xx Access Point Product Reference Guide A 12...
Page 614: ...AP 51xx Access Point Product Reference Guide C 4...
Page 620: ...AP 51xx Access Point Product Reference Guide IN 10...
Page 621: ......