Advanced TroubleShooting
Check the heating element - it may be
damaged. See “Replacing the Thermal
Fuse” and “Replacing the Water Level
Sensor”
M E S S A G E
T R I G G E R
P R O B A B L E C AU S E
C O R R E C T I V E A C T I O N
WATER TANK
Spa Steam
Water tank is full
Do not add water
FULL!
generator is full
Start the steam session
Water level sensor(s)
Check the connection
plug is loose
between Sensor & PC board
Thermal fuse is blown
STEAM ACTIVATING
ON MENU IS OK
BUT NO STEAM
IS EMMITTED
Hood is open
Close hood
Water level sensor(s)
Check the connection
plug is loose
between Sensor & PC board
Water level sensor(s) faulty
See “Replacing the Thermal
Fuse” and “Replacing the
Heating element is burned
See “Replacing the Heating
Element”
VIBRATORY BED DOESN’T FUNCTION
Plug is loose
Check plug connection under the
vibratory bed
S T E A M P R O B L E M S
You are using aromatics, or dirty water.
Replace water in the steam generator tank see section 11.5
The following are not signs of malfunction:
C O N D I T I O N
C A U S E
Bubbling sound during use.
This is caused by the water moving from the tank into
the steam jets.
Water spurting out from steam jets during use.
This cause by using non-distilled, aromatic or dirty water.
Takes long time for steam vapor to appear.
It takes some time for steam to start after pressing the
operation button. In depend on the temperature
and humidity in side the treatment room.
Water drops.
Water drops may form from condensation inside
the capsule as a result of temperature or humidity
change. Make sure to wipe it dry inside before
each use. Maintain out surfaces dry to avoid water stains.