4 . 1
|
E L E C T R I C A L I N S T A L L A T I O N R E Q U I R E M E N T S
The unit’s power supply must be shut off prior to installation and/or any work on the unit.
The Dermalife
®
Spa Feng Shui
™
2G System should be used with AC 220, 50/60 Hz.
CAUTION:
To prevent electric shocks and fire hazards, do
NOT
use any other power source.
Because of the special nature of this device, an entire circuit needs to be dedicated to the operation of the
Dermalife Spa Feng Shui 2G System. Each individual Dermalife Spa Feng Shui 2G System should have its own
dedicated circuit breaker. The current draw depends on the voltage and is rated at 13.41 amps for 220 volts
when Radiant Heat and Steam are running.
The unit is designed for use in current circuits where either a neutral conductor or a stationary protective
conductor with equivalent potential is available — system TN-S. It is strictly prohibited to use the unit in
alternating current circuits TT and IT.
Unit electrical specifications: 13A, 220V, 50/60Hz.
For electrical installation, the right hand side panel of the unit must be removed.
Place the unit on a level surface.
Make sure the cover can be opened without hitting the ceiling. Check the SPECIFICATIONS SECTION for more details
of the dimensions.
Do not install the unit near heat sources such as radiators, or in places subject to excessive dust, mechanical
vibration, shock or heat.
Do not block the air inlet of the face fan located on top of the unit (hood).
If the unit is located in a cold location, the supporting hood strut may decrease pressure in the strut chambers, which
may cause the hood to drop sharply. The operating temperature range for the struts is from 50 to 180°F (15 to 80°C).
The unit must be connected to the electricity system stationary according to the following:
S p a F e n g S h u i - P a g e 7
2 0 6 3 6 5 R e v. 8 0 9 U F S . 1 0 . 8 0 9 . 7. U
SECTION 4 |
Electrical & Plumbing Requirements
Owner’s Manual
NOTE:
Only a qualified/certified/licensed electrician is authorized to make the electrical connections/installation of this
unit strictly according to all local electrical installation requirements. All local electrical installation requirements and
loading value for one phase must be observed when carrying out electrical installation or connections.
Spa Feng Shui Manual 809.qxp:DL_SFS_806 A4 NS 9/18/08 4:13 PM Page 11