9 . 5
|
T E M P E R A T U R E S E N S O R
•
Required tools:
large pliers
•
The temperature sensor is inserted through
the hood and secured with a nut. The nut is
round and pliers are required for its removal.
•
The sensor is connected to “LCDrb” in LCD
housing. See “Opening the LCD Housing”
and “Replacing Parts in the LCD Housing”
on the following pages for information on
disconnecting wiring.
Name
Part Number
Temperature sensor
E4000-32
9 . 6
|
O P E N I N G T H E L C D
H O U S I N G
•
Required tools: crosshead screwdriver
•
Move LCD housing position as shown in the
figure below.
•
Remove nine (9) screws.
•
Keep two (2) housing parts together and
turn it to the horizontal position, then lift
the upper part.
•
To tighten LCD housing, turn two (2) nuts
located on the left and right side of the
housing clockwise.
S p a F e n g S h u i - P a g e 2 7
2 0 6 3 6 5 R e v. 8 0 9 U F S . 1 0 . 8 0 9 . 7. U
Owner’s Manual
SECTION 9 |
Service for Sensors and LCD Housing
( Figure C. Principal Scheme Devices in Hood)