![SWIT Electronics FM-24DCI User Manual Download Page 26](http://html1.mh-extra.com/html/swit-electronics/fm-24dci/fm-24dci_user-manual_1415517026.webp)
Items
Default Value Domain Range
Description
METER
level meter.
METER
SELECT
CH1-2
CH1-2
G1
G2
G3
G4
G1+G2
G1+G3
G1+G4
G2+G3
G2+G4
G3+G4
G1-4
Used to select the audio
channels that will be shown in
the audio meter display. Each
G* represents four channels,
and each CH* represents a
channel with specified number.
METER
DIRECTION
HORIZONTAL
VERTICAL
HORIZONTAL
Used to set the displayed
direction of audio meter.
METER
POSITION
BOT LEFT/
BOTTOM
When METER DIRECTION is
set as VERTICAL
, choose one of the followings:
BOT LEFT: bottom left
BOT RIGHT: bottom
right
TOP RIGHT: top right
TOP LEFT: top left
When METER DIRECTION is
set as HORIZONTAL, choose
one of the followings:
BOTTOM
TOP
Used to set the displayed
position of audio meter.
METER DIS
MODE
MODE1
MODE1: simple audio
meter
MODE2: audio meter
with channel number
MODE3: audio meter
with channel number
and dB value
Used to set the displayed mode
for audio meter.
REF LEVEL
-20dB
-20dB/-18dB
Set the reference level
OVER LEVEL -10dB
-10dB
-8dB
-6dB
-4dB
-2dB
Set the overload level
AUDIO LEVEL METER
The appearance of Audio Level Meter is as shown in Figure 5.1-12: