SVS-VISTEK
Feature description
67
6.3.9
Serial data interfaces
(ANSI EIA/) TIA-232-F
RS-232 and RS-422 (from EIA, read as Radio Sector or commonly as
Recommended Standard) are technical standards to specify electrical
characteristics of digital signaling circuits.
In the SVCam’s these signals are used to send low-power data signals to
control light or lenses (MFT).
serial interface parameter – RS-232 and RS-422
RS-232
It is splitted into 2 lines receiving and transferring Data.
RXD
receive data
TXD
transmit data
Signal voltage values are:
low:
-3 … -15 V
high:
+3 … +15 V
With restrictions: refer to Table: serial interface parameter above.
Data transportis asynchronous. Synchronization is implemented by fist and
last bit of a package. Therefore the last bit can be longer, e.g. 1.5 or 2
times the bit duration). Datarate (bits per second) must be defined before
transmission.
Serial interface Parameter
RS-232
RS-422
Maximum open-circuit voltage
±25 V
±6 V
Max Differential Voltage
25 V
10 V
Min. Signal Range
±3 V
2 V
Max. Signal Range
±15V
10 V
Summary of Contents for HR Series
Page 1: ...2 06 2019 Manual HR Camera Link hr25 hr29 hr43 hr120 ...
Page 5: ...SVS VISTEK Safety Messages Contents of Camera Set 5 ...
Page 14: ...SVS VISTEK Connectors 14 ...
Page 64: ...SVS VISTEK Feature description 64 will reflect as following ...
Page 85: ...SVS VISTEK Dimensions 85 8 1 hr25 CL ...
Page 86: ...SVS VISTEK Dimensions 86 ...
Page 87: ...SVS VISTEK Dimensions 87 ...
Page 88: ...SVS VISTEK Dimensions 88 8 2 hr29 CL ...
Page 89: ...SVS VISTEK Dimensions 89 ...
Page 90: ...SVS VISTEK Dimensions 90 ...
Page 91: ...SVS VISTEK Dimensions 91 8 3 hr43 CL ...
Page 92: ...SVS VISTEK Dimensions 92 ...
Page 93: ...SVS VISTEK Dimensions 93 ...
Page 95: ...SVS VISTEK Dimensions 95 ...
Page 96: ...SVS VISTEK Dimensions 96 ...