SVS-VISTEK
Feature description
63
Sequencer setup with SVCapture
Starting with SVCapture 2.5.2, there is a sequencer assistant, providing
easy setup of the sequencer settings. The assistant will help you to setup
timings for start exposure and lighting and so on. The PWMs are
connected to the physical outputs (e.g. for driving LED lights)..
For making the sequencer work in general, have a look into the
GenICam tree or even more simple into the I/O assistant. Connect the
the I/O lines as below:
You may start the sequence with a hardware trigger input signal
(sequencer is connected to Input 1). As an alternative you might use a
software trigger. For software trigger setup, adjust as below:
Feature Name
Feature Value
Acquisition Control - Acquisition Mode
Continuous
Acquisition Control – Trigger Selector - Trigger Mode On
Acquisition Control – Trigger Selector - Trigger
Source
Line 1
Acquisition Control – Trigger Selector – Exposure
Mode
Trigger Width
Enhanced IO – PWMEnable
On
Enhanced IO – SeqEnable
On
The Exposure mode „trigger width“ makes exposure start at a certain
timing (Seq pulse A) and stop at Seq pulse B. In the GenICam tree this
Summary of Contents for HR Series
Page 1: ...2 06 2019 Manual HR Camera Link hr25 hr29 hr43 hr120 ...
Page 5: ...SVS VISTEK Safety Messages Contents of Camera Set 5 ...
Page 14: ...SVS VISTEK Connectors 14 ...
Page 64: ...SVS VISTEK Feature description 64 will reflect as following ...
Page 85: ...SVS VISTEK Dimensions 85 8 1 hr25 CL ...
Page 86: ...SVS VISTEK Dimensions 86 ...
Page 87: ...SVS VISTEK Dimensions 87 ...
Page 88: ...SVS VISTEK Dimensions 88 8 2 hr29 CL ...
Page 89: ...SVS VISTEK Dimensions 89 ...
Page 90: ...SVS VISTEK Dimensions 90 ...
Page 91: ...SVS VISTEK Dimensions 91 8 3 hr43 CL ...
Page 92: ...SVS VISTEK Dimensions 92 ...
Page 93: ...SVS VISTEK Dimensions 93 ...
Page 95: ...SVS VISTEK Dimensions 95 ...
Page 96: ...SVS VISTEK Dimensions 96 ...