SVS-VISTEK
Feature description
61
As being said before, all these values have to be entered into the
camera’s GenICam tree as tic values.
The timing values translate like this into tics:
Values to set in GenICam
properties
Interval 0 (RED)
Interval 1 (GREEN)
Interval 2 (BLUE) Interval 3 (WHITE)
Sequencer Interval
66666667 tic
(1000 ms)
66666667 tic
(1000 ms)
66666667 tic
(1000 ms)
66666667 tic
(1000 ms)
Seq pulse A start
0 tic
(0 ms)
0 tic
(0 ms)
6666667 tic
(100 ms)
0 tic
(0 ms)
Seq pulse A stop
6666667 tic
(100 ms)
20000000 tic
(300 ms)
20000000 tic
(300 ms)
6666667 tic
(100 ms)
Seq pulse B start
0 tic
(0 ms)
6666667 tic
(100 ms)
13333333 tic
(200 ms)
0 tic
(0 ms)
Seq pulse B stop
6666667 tic
(100 ms)
13333333 tic
(200 ms)
20000000 tic
(300 ms)
2200000 tic
(33 ms)
Effective exposure time
100 ms
100 ms
100 ms
33 ms
PWM Frequency f
66667 tic
(1000 Hz)
66667 tic
(1000 Hz)
66667 tic
(1000 Hz)
66667 tic
(1000 Hz)
PWM change 0 (RED)
66667 tic
(100% of 1000 Hz)
0 tic
0 tic
66667 tic
(100% of 1000 Hz)
PWM change 1 (GREEN)
0 tic
46667 tic
(70% of 1000 Hz)
0 tic
46667 tic
(70% of 1000 Hz)
PWM change 2 (BLUE)
0 tic
0 tic
53333 tic
(80% of 1000 Hz)
53333 tic
(80% of 1000 Hz)
PWM change 3
-
-
-
-
Summary of Contents for HR Series
Page 1: ...2 06 2019 Manual HR Camera Link hr25 hr29 hr43 hr120 ...
Page 5: ...SVS VISTEK Safety Messages Contents of Camera Set 5 ...
Page 14: ...SVS VISTEK Connectors 14 ...
Page 64: ...SVS VISTEK Feature description 64 will reflect as following ...
Page 85: ...SVS VISTEK Dimensions 85 8 1 hr25 CL ...
Page 86: ...SVS VISTEK Dimensions 86 ...
Page 87: ...SVS VISTEK Dimensions 87 ...
Page 88: ...SVS VISTEK Dimensions 88 8 2 hr29 CL ...
Page 89: ...SVS VISTEK Dimensions 89 ...
Page 90: ...SVS VISTEK Dimensions 90 ...
Page 91: ...SVS VISTEK Dimensions 91 8 3 hr43 CL ...
Page 92: ...SVS VISTEK Dimensions 92 ...
Page 93: ...SVS VISTEK Dimensions 93 ...
Page 95: ...SVS VISTEK Dimensions 95 ...
Page 96: ...SVS VISTEK Dimensions 96 ...